1. SAIP limit switch
2. OEM service
3. CE & RoSH certificate
4. 2 years warranty
5.Our company strength
FeaturesStrong metal outer shell, swing arm max. 95Long life (20, 000, 000 mechanical operations)Stainless steel idler wheel, punch and springSelective PG11 cable gland bernstein limit switch |
Specifications Model | CSA | CSA-001 | CSA-003 | CSA-012 | CSA-021 | CSA-031 | CSA-061 | CSA-071 | CSA-081 | Operating force | OF Max. | 800g | 800g | 800g | 400g-cm | 400g-cm | 150g | 150g | 150g | Release force | RF Min. | 400g | 400g | 400g | 100g-cm | 100g-cm | 50g | 50g | 50g | Pre-travel | PT Max. | 1.8mm | 1.8mm | 1.8mm | 20 º | 20 º | 30mm | 30mm | 30mm | Travel position | TP ± 10% | 2.0mm | 2.0mm | 2.0mm | 22.5 º | 22.5 º | 22.5 º | 22.5 º | 22.5 º | Movement differential | MD Max. | 1.2mm | 1.2mm | 1.2mm | 10 º | 10 º | 14 º | 14 º | 14 º | Over travel | OT Min. | 4.0mm | 4.0mm | 4.0mm | 75 º | 75 º | 20mm | 20mm | 20mm | Total travel | TT Min. | 5.8mm | 5.8mm | 5.8mm | 95 º | 95 º | 50mm | 50mm | 50mm | Rotary indexing | | | | | 22.5 º | 22.5 º | | | | Characteristics Double Break Mechanism | INO+INC Force Break snap action | Rated Voltage/Current | 10(4)A, 125, 250VAC/6(2)A, 380VAC For inductance Load, CosØ =0.4 | Contact Resistance | 25mΩ max. (initial value) | Insulation Resistance | 100mΩ min. (at 500VDC) | Dielectric Strength | 1000VAC, 50/60 HZ for 1 minute between terminals of the same polarity | 1500VAC, 50/60 HZ for 1 minute between current-carrying and non-current-carrying metal parts | 1500VAC, 50/60 HZ for 1 minute between each terminal and ground | Electrical Life | 500,000 at 10A 250VAC Resistive | Mechanical Life | 10, 000, 000 operations min. (under rated conditions) | Operating Speed | 5mm/s to 0.5m/s | Degree of Protection | IP65 | Ambient Temperature Rised | Max 30 over ambient temperature at rated voltage/current | Conformed Standards | Cenelec EN 50041, EN 50047, IEC 337-1, VDE 0660 | Operating Temperature | -5 ~+65 (with no icing) | Storage Temperature | -5 ~+65 (with no icing) | Ambient Operating Humidity | 95 RH Max. | Shock Resistance | Mechanical durable: 1000m/s2 min. | Malfunction: 300m/s2 min. | Vibration Frequency | Malfunction: 10 to 55HZ, 1.5mm double amplitude | Terminal Screw Torsional Force | 6-8 kgf-cm | Other Screw Torsional Force | Cover 12-14 kgf-cm/Head 8-9 kgf-cm/Mounting 50-60 kgf/cm | Bare Wire Diameter | Ø2 Max | Cable Diameter | Ø12 Max(IP 65 if use cable 8-9) |
|
CSA Limit Switch
2012 Newest saip limit switch