Mixing Valve
HDSafe Technologies Co., Ltd. [China]
Detailed Product Description
Technical Performance Parameter:
1) Work Water Pressure: 0.05-1Mpa (Exceeding 0.5Mpa Recommend to install controlling
of flow rate equipment)
2) Perfect Water Pressure: 0.05-0.5Mpa
3) Scope of Cold Water Temperature:5-29oC
4) Scope of Hot Water Temperature: 50-80oC
5) Scope of Adjustable Temperature: 20-50oC
6) Safety Temperature Key: 38oC
7) Result of Unavailable Cold Water: When exceeding 5seconds of unavailable cold
water, valve will control water flowing rate to 1.9Litre/Minute, volume of flowing
water ≤150ml, temperature of water≤49oC
8) Life of Valve:CSA B125-98 ASSE 1016 (≤100,000 Cycle)