Main Features:1. LCD digital display will show voltage, frequency, battery and load information.2. Built in AC charger will charge batteries automatically.3. High-frequency switching technology for compact size and light weight4. Pure sine wave output (THD<3%) for wide range of applications and harsh environment5. High efficient DC-to-AC conversion minimizing energy loss6. N+X parallel redundancy framework design for future expansion7. "All master" dynamic mechanism eliminate single point failure to optimize reliability8. Low power "Power Saving Mode" to conserve energy for less than 15W9. High power density design  10. Input/output isolated design for the maximum operation safety11. Intelligent cooling fan speed control determined by loads12. Comprehensive status LED indicators13. DSP Control14. Multiple protection: Input low voltage / Overload / Short circuit / Low battery alarm / Input over voltage / over temperature15. Wall-Mount design for flexible placement 

Main technical parameters

Inverter Mode Specifications

MODEL

PSC5K-48

PSC5K-96

Output Voltage Waveform

Pure Sine Wave

Rated Output Power(VA)

5000

Power Factor

0.84

Nominal Output Voltage(V)

230Vac

Output Frequency(Hz)

50Hz / 60Hz ± 1Hz

Output Voltage Regulation

±10% rms

Nominal Efficiency

>90%

Over-Load Protection

fault after 5s@≥150% load,

fault after 10s@110%~150% load,

Surge rating

10000VA

Capable of starting electric motor

2.5HP

Output Short Circuit Protection

Current limit (Fault after 4 cycles max)

Bypass Breaker Size

40A

Nominal DC Input Voltage

48V

96V

Min DC start voltage

40V

80V

Low DC Alarm

42.0 ± 1.2Vdc

84.0± 2.4Vdc

Low DC Alarm Recovery

43.2 ± 1.2Vdc

86.4± 2.4Vdc

Low DC Shut-down

40.0±1.2Vdc

80.0±2.4Vdc

Low DC Shut-down Recovery

44.0±1.2Vdc

88.0±2.4Vdc

High DC Shut-down

60.0±1.2Vdc

120.0 ±2.4Vdc

High DC Shut-down Recoveryµ

58.0±1.2Vdc

116.0 ±2.4Vdc

Power saver setting

0W (Set “OFF” at LCD)

10±5W enter 5+/-2w leave (Set “ON” at LCD)

Tare loss(nominal)

Saver OFF:<50w

Saver ON:<10w

DC component of AC output

<100mv

Half wave load detection

Yes(when unbalance current>35A)

µ Note: Necessary condition for DC low recovery is: Line voltage must be available for charging.

Any doubts about this item,please contact Vicky for more infomation!

Solar power inverter with charger, DC to AC,LCD display,Pure sine wave,High frequency

Ads by Google


About Us | Contact Us | Help | Terms & Conditions
Hot Products: A | B | C | D | E | F | G | H | I | J | K | L | M | N | O | P | Q | R | S | T | U | V | W | X | Y | Z | 0-9
Copyright Notice @ 2008-2022 ECBAY Limited and/or its subsidiaries and licensors. All rights reserved.