plant inverter,power plant,power plant
plant inverter,power plant,power plant is specially-designed for the NorthAmericamarket.rated power under55degwithoutderatin
plant inverter,power plant,power plant
General Descriptions: | |||
SG100K3 is using low-frequency isolation transformer for outdoor applications. It can be continuously operating at rated power under +55 without derating. It is the ideal product used for string-connected large PV power station to simplify PV power plant design. In addition, wider input voltage range ensures more combinations of the PV arrays. It is one of the highest cost-effective grid-connected inverters in the world. | |||
Technical Features: | |||
Wide DC input voltage range | |||
High conversion efficiency up to 97% (with transformer) | |||
Advanced IGBT module boosts reliability and stability | |||
Complete protection features ensures greater reliability of the system | |||
Easy installation and use | |||
Accurate output power measurement | |||
Multi-lingual LCD display & Multiple communication interfaces | |||
Can be continuously operating at rated power under +55 without derating | |||
DK5940, TüV & CE certification, CGC SOLAR Certification | |||
Communications: | |||
RS485/Ethernet/GPRS interfaces | |||
Computer monitoring software | |||
Safety: | |||
·Full protection functions: over-voltage protection, short-circuit protection, islanding protection, over-heat protection | |||
·Over-load protection | |||
·Standards complied: EN61000-6-1, EN61000-6-2, EN61000-6-3, EN61000-6-4,EN61000-3-2, EN61000-3-3, EN60164-1-1,EN55022, EN50178, DK5940, TüV | |||
| |||
Technical Specifications | |||
MODEL | SG100K3 | ||
DC INPUT | |||
Max. DC Voltage | 880Vdc | ||
MPPT Range | 450~820Vdc | ||
Max. DC Power | 110kWp | ||
Max. Input Current | 250A | ||
Max. Number of Strings | 6 | ||
AC OUTPUT | |||
Output Power | 100kW | ||
Operating Voltage | 400Vac | ||
Nominal Current | 145A | ||
Grid Structure | TT, TN-C, TC-S | ||
Operating Frequency | 50Hz/60Hz | ||
Voltage Ripple, PV Voltage | < 3% | ||
Current THD | < 3% (at nominal power) | ||
Power Factor | 0.99 (at nominal power) | ||
SYSTEM | |||
Max. Efficiency | 97.00% | ||
Euro Efficiency | 96.40% | ||
Protection Degree | IP20 (indoor) | ||
Operating Temp. | -20~+55 C | ||
Ventilation Method | controlled forced-air cooling | ||
Humidity | 0~95%, non-condensing | ||
Display | LCD | ||
Comm. Interfaces | RS485 | ||
optional | Ethernet/GPRS | ||
Self-Consumption in Operation | <1% of Pnom | ||
Standby Power Consumption | <30W | ||
External Auxiliary Voltage | 230V, 50Hz/60Hz | ||
Ground Fault Monitoring | Yes | ||
Emergency Stop | Yes | ||
Power Switch AC Side | Yes | ||
Power Switch DC Side | Yes | ||
Fresh Air Consumption | 1620m /h3 | ||
MECHANICAL DATA | |||
W | H | D | 1020 | 1964 | 770 (mm) | ||
Weight | 900kg | ||
STANDARDS | |||
EMC | EN61000-6-2, EN61000-6-4 | ||
Safety | EN50178, IEC62109 | ||
CE Conformity | Yes | ||
Others | RD1663/2000, DK5940 |