Welcome to ECBAY
FST-600 high-performance VFD for pump and fan
FST-600 high-performance VFD for pump and fan

dedicted in pump and fan application. 1.5KW-630KW

Application

This VFD is suitable for high-end application area with high precision, fast response, high torque, big inertia, potential load etc.

Main features

SPWM control. Stable operation with rated torque at low speed Fast adaptation to the varying load, high-efficiency voltage output, automatic regulation of V/F characteristics for variable load. Built-in RS-485 communication interface, fully supporting MODBUS Protocol. Advanced design of automatic torque compensation maximally optimizes the system’s performance. Presentable operation modes enable the machine to work more efficiently. This VFD has 28 kinds of protecting and warning functions. Built in PID regulator which has more convenient regulating function. Online monitoring and adjusting function over variable parameters.

   Technical Specifications (VFD)

Item

Specification

Output

Output rated voltage

Max. output voltage is the same as the input power supply voltage

Suitable motor power (kW)

15

22

3.7

5.5

75

11

15

185

22

30

37

45

55

75

93

110

Output rated current (A)

4.8

62

8

14

18

27

34

41

52

65

80

96

128

165

180

224

Suitable motor power (kW)

132

160

185

200

220

245

280

315

355

400

500

560

630

710

800

1000

Output rated current (A)

260

302

340

380

450

470

530

605

660

750

940

1050

1200

1300

1500

1860

Ration

100% continuous

Max. overload current

G: 150% 1min, 180% 6sec (P series: 120%1min, 140% 18sec)

Powersupply

Rated voltage & frequency

3 phase 380V (+10% ~ -15%) 50/60Hz±5%

Control

charac-ters

Frequency range

0 ~ 400jHz

Frequency accuracy

Digital command±0.01%(-10°C ~ +40°C)

Set frequency resolution

Digital command 0.1 Hz; analogue command 0.1 Hz

Output freq. resolution

0.1Hz

Overload durance

G series: 150% of output rated current 1min, P series: 120% of outputrated current 1min

Frequency set signal

0-+10V (20kQ) 4~20mA (250Q)

Accel / Decel feature

0.1~3600sec (Accel/Decel time is set separately)

Brake torque

125% with additional brake resistor

V/f pattern

15 fixed V/F features selectable, any V/F features can be set

Protection

Over voltage, Under voltage, Over current, Overload, Electronic thermalrelay, Overheat, Over voltage stalling

Environment

Temperature / humidity

-10°C ~ +40°C / 20 ~ 90% RH (no dewing)

Installed place

In door(no corrosive gas), No higher than 1000m above sea level, with-out dust, corrosive air and direct sunlight

Vibration

Lower than 0.2g when below 20Hz

Cooling method

Forced air cooling