300w to 5000w home ups inverter
home ups inverter 1.Wide arrange input voltage 2.Battery charger inside 3.DC to AC inverter 4.Pure sine wave
300w to 5000w home ups inverter
Feature.
Pure sine-wave output;25A battery charge current;Superior performance from CPU control technology;Wide range of input voltage, accurate output, AVR function;Inner-Equipped protection for over-load, short-circuit, over-voltage, low-voltage, over- heating, etc.Easy to check with inverter condition with concise LED indication that can be upgraded to LCD.Generator compatibly and external battery connection achievable.Intelligent battery management with protection against over-charged and over-discharged etc.Special charging system design for better protection of battery life. Compatible with generators and suitable for harsh environment where power voltage is extremely unstable. With standard on-line structure (three ports) and can be used as UPS.Extremely low return noise and no disturbance to talking quality.Technical specifications:
NT Series 300W-20000W Technical Specification | ||||||||||||||
MODEL P-R | 601 | 102 | 122 | 152 | 202 | 302 | 362 | 402 | 502 | 602 | 752 | 103 | 1512 | 2016 |
Rated capaclty(W) | 600W | 1000W | 1200W | 1500W | 2000W | 3000W | 3600W | 4000W | 5000W | 6000W | 7000W | 10000W | 15KVA/12KW | 20KVA/16KW |
INPUT | ||||||||||||||
Phase | Single | |||||||||||||
Voltage | 100/110/120/127/220/230VAC(+25%,-35%) | 100/110/120/127/220/230VAC±20% | ||||||||||||
Frequency Range | 60/50±10%(auto sensing) | |||||||||||||
OUTPUT | ||||||||||||||
Phase | Single | |||||||||||||
Voltage (Batt Mode) | 100/110/120/127/220/230VAC/240VAC | |||||||||||||
Frequency Range(Batt Mode) | 60/50±0.2Hz | |||||||||||||
Transfer Time | Typical 2-6ms ,10ms max | |||||||||||||
waveform | Pure Sine Wave | |||||||||||||
BATTERY | ||||||||||||||
Recharge Current(S) | 25Amax | |||||||||||||
Nominal DC input voltage | 12VDC | 12/24VDC | 24VDC | 24VDC | 24/48VDCVDC | 48VDC | 48VDC | 96VDC | 192VDC | |||||
INDICATORS | ||||||||||||||
LCD/LED | Optional | |||||||||||||
PROTECTION | ||||||||||||||
Overload | IPS automatically shutdown if overload exceeds 120% ofnormal value for 30 secondsIPS automatically resume work if overload comes back to rated load | |||||||||||||
Short circuit | Cut off immediately | |||||||||||||
ALARM | ||||||||||||||
Battery back-up | Sounding every 4 second | |||||||||||||
Low Battery | Sounding every second | |||||||||||||
Overload | Audible alarm | |||||||||||||
Fault | Continuously sounding | |||||||||||||
OPERATING ENVIRONMENT | ||||||||||||||
Humidity | 0-90%RH @-5-55°C(non-condenslng) | |||||||||||||
Noise Level | Less than 60dB | |||||||||||||
Appearance | ||||||||||||||
External Size(mm)L*W*H | 375*130*190 | 452*192*338 | 500*260*455 | 570*260*750 | ||||||||||
Carton Size(mm)L*W*H | 478*463*315(2 Piece) | 584*335*495(1 Piece) | 545*345*535(1 Piece) | 720*480*1030(1 Piece) | ||||||||||
Unit weight(kg/pc) | 10 | 13.2 | 17 | 24.2 | 27.4 | 29.5 | 33 | 33 | 35/52 | 55 | 69 | 70 | 76 | 79 |
Gross weight(kg/ctn) | 22.6 | 29 | 19.7 | 26.9 | 30.1 | 33.2 | 35.7 | 35.7 | 49/66 | 69 | 83 | 84 | 88 | 92 |