ZHS-SP Energy-saving low dew point special dehumidifier various models of reference technology parameters

model

items

Total dehumidification quantity

Kg/h

Processing air volume

m³/h

Regenerative way

*KW

Regenerative way

(Electric )KW

Cold load

KW

Dehumidification space

Chiller power

KW

ZHS-250

6.2~15

300~1200

 ————

5.6~7

18~35

30~50

5.9~

11.5

ZHS-350

12.5~19.8

600~2400

 ————

11~22

18~43

50~80

5.9~

14.2

ZHS-450

17.2~31.4

1200~5000

4.5~7

15~28

43~86

80~150

14.2~

28.4

ZHS-550

32~62

2400~8000

5~13

22.5~36

38~120

150~300

12.5~

39.6

ZHS-770

50~130

5000~9500

5.5

43~80

45~136

300~

 450

14.9~

44.9

ZHS950

70~220

7000~15000

7.5

68~110

72~174

450~   750

23.8~

52.2

ZHS-1200

150~420

10000~28000

13~18

116~220

132~ 356

750~ 1400

43.6~

106.8

ZHS-1500

250~780

15000~43000

22~27

————

183~ 566

1400~ 2150

54.9~

169.8

ZHS-1900

320~960

20000~75000

28~36

————

290~ 901

2150~ 3500

87~

270.3

ZHS-2400

380~1300

30000~115000

42~53

————

495~ 1397

3500~ 5750

148.5~419.1

ZHS-3000

720~2100

45000~150000

75~88

————

620~ 1820

5720~ 7500

186~

546

Attention:

1.Wheel surface wind speed:_____m/s design

2.To protect person normal breathing and dry room positive pressure, the researchers add fresh 20 to 30 m ³ / h, positive pressure air dry room of volume--according to The Times computation, and both take the maximum. Fresh air condition according to temperature and measunnent °C, relative humidity, absolutely 70% moisture content 26.8 g/kg dry air

3.Person's wet load press ___ g/h calculation, researchers must be approved by the warm rushed into the dry room between work again

4.Regenerative way * can choose steam, fuel oil, natural gas ,  liquefied gas and City gas pipeline.

5.ZHS70~ZHS3000 Wheel dehumidifier power does not contain dehumidification power  and air supply fan power. Power: three-phase 380V50HZ

6.ZHS-450~ZHS-770 refrigerants can use straight turgor air-filled type refrigeration unit, ZHS-950~ZHS-3000 can use water-cooled chiller

7.The overall size can according to the user's actual situation

8.Because the technology constantly updated, the actual technology parameter for the technical parameters of manufacturer shall prevail.

Related Products
Ads by Google


About Us | Contact Us | Help | Terms & Conditions
Hot Products: A | B | C | D | E | F | G | H | I | J | K | L | M | N | O | P | Q | R | S | T | U | V | W | X | Y | Z | 0-9
Copyright Notice @ 2008-2022 ECBAY Limited and/or its subsidiaries and licensors. All rights reserved.