Welcome to ECBAY
counter,counters, industrical counter
counter,counters, industrical counter

Detailed Product Description


Wl99 bagged digital counter 

Function and purpose:

1            Single bag counting: available for automatic absorption of interference pulse on cement bags and belt for precise counting. 

2            Connected bags counting: set normal parameters of each bag so that the number of continuous bags can be identified intelligently according to the parameters of a single bag.

3            Batch counting: available for setting and displaying the number of single bags (0-60000); when the number reaches the setting value, counter will output flash alarm signal AL and a set of switching control signals (5A).

4            When the counting number reaches the setting value, counter will be reset automatically or manually; then input code to reset counter according to requirement. 

5            Advanced alarm before reaching the setting value for batch: the bags before alarm can be set by inputting code according to requirement.

6            Accumulation of total number: check the total number of counts (0-9999999) (reset by inputting code)

7            Malfunction alarm: when inductive head is detected abnormal or continuous bags exceeds 10 bags, the counter will send a set of relay switching signals for alarm (5A); this switch can connect to alarm bell or stop belt. 

8            Automatic Control: Relay switching signals can realize automatic control of the secondary circuit of packaging line. (Such as control packing machine, belt, pushing machine and loader as well as connect to alarm bell etc.)

Main technical parameters:

1

Rated power voltage:

220V

2

Range of operating voltage

85-110% of rated voltage

3

Count input mode

optoelectronic input, .proximity switch input

4

Counting range

Batch counting: 0-60000

Accumulative counting: 0-99999999

5

Working model

accumulative counting

6

Identification of continuous cement bags

2-10 bags

7

Supply power consumption

25W

8

Operating ambient temperature

-10+50 C without condensed water.

9

Reset mode

manual/automatic reset

10

Output contact

normally open and closed

11

Maintenance

keep opposite photoelectric switches aligned and inductive head clean.