Welcome to ECBAY
Small finger pulse oximeter with Led display for Adults and pediatrics
Small finger pulse oximeter with Led display for Adults and pediatrics

Small finger pulse oximeter with Led display SPO2, PR top quality with CE certificate and long working life

Small finger pulse oximeter with Led display for Adults and pediatrics

 

 

 

 

The Scope of Application 

Pulse oximeter is a very important and common device to check patient blood-oxygen saturation (SpO2) level and pulse rate. As a small, compact, simple, reliable and durable physiological monitoring device, Fingertip pulse oximeter greatly enhances patient care. It is widely applied in clinic, hospital, social medical organizations, first aid, and homecare etc.

Features 

1. Small & lightweight design

2. Digital LEDs display

3. Display SpO2, PR, and Pulse bar 

4. Low power consumption; automatically power off 

5. Battery-low indicator

6. 2 AAA alkaline or rechargeable batteries

7. Accommodates widest range of finger sizes from pediatric to adult

Technical Specifications  

Patient Range

Adult and Pediatrics

SpO2

Measurement range                   70% - 99%

Resolution                           ±1%

Measurement accuracy                80% - 99%: ±2%

70% - 79%: ±3%

≤69%: No definition

Pulse Rate

Measurement range                   30 - 235bpm

Resolution                           ±1bpm

Measurement accuracy                30 - 99bpm: ±2bpm

100 - 235bpm: ±2%

Display

Type                                Digital LEDs display

Parameters                          SpO2, PR, Pulse bar

Mode                                1 display mode

Alarm

Alarm                               Battery-low indicator

Mechanical

Dimension      58mm (L) * 32mm (W) * 34mm (H)

Weight         50g (including batteries)

Battery

Two AAA 1.5V, 600mAh alkaline batteries could be continuously operated as long as 30 hours.

Environmental

Operation Temperature    5°C - 40°C

Storage Temperature     -20°C- 55°C

Operation Humidity       ≤80%, no condensation

Storage Humidity         ≤93%, no condensation

Measurement Performance in Low Perfusion Condition 

Required the test equipment (BIO-TEK INDEX Pulse Oximeter tester) the pulse wave is available without failure when the simulation pulse wave amplitude is at 0.6%.

Interference Resistance Capacity against Ambient Light

Device works normally when mixed noise produced by BIO-TEK INDEX Pulse Oximeter tester.

 