1) biogas generator set 2) low operation cost 3) Well performed control system

specifications of  biogas generator set:

1) Longer life: natural gas engine has a life of over several years if it is properly

    operated and maintained

2) Low operation cost: natural gas has a rich reserve with low cost and a high

    rate of return

3) High profit: low operation cost, supply of electricity and thermal power at the

    same time, low maintenance cost

4) Coupled with brushless alternators of Leroy Somer / Engga

5) Well performed control system, high quality monitor instrument, with sound

    and light alarm devices, auto shutdown

6) Protection function: over-current, under-voltage, auto-regulate voltage,

    reverse power

7) Monitor function: speed, water temperature, lube-oil temperature, lube-oil

    pressure, exhaust temperature

8) Gas consumption: less than 0.33cbm/kWh                                     

9) Supply connection: 3 phase, 4 lines             

10) Rated voltage: 400V

11) Rated speed: 1,500rpm/1,800rpm                      

12) Rated frequency: 50Hz / 60Hz

13) Rated power factor: 0.8 

14) Exciting way: brushless

15) Starting mode: 24V DC electric starting system  

16) Cooling mode: closed-circuit cooling system

 

 

 

matters need attention

1). The diesel engine room open flame is strictly prohibited

2). The diesel engine room if there is a hot work, must be approved by the leaders issued hot working ticket, and make all the fire prevention measures

3). Units in full load operation, the oil temperature should be between 82-107 degrees, if the oil temperature rise suddenly, the reason is not load jumpstart cause, likely a mechanical problem and shall immediately report unit long, and checked

4). Temperature lubricating oil in 60 degrees, the continuous long time running, may cause the crankcase oil temperature within the acidification, it will speed up the machine of wear and tear

5). Cooling water temperature in the 71-90 degrees is the best range, machine parts of the formation of the relative inflation clearance, favorable to operation condition, or higher than 105 5% protection movement

6). Diesel generator may not long time of no-load running, because when the temperature of the combustion chamber no-load running low, fall to fuel incomplete combustion, will cause the separation in combustion nozzle carbon block and piston rings, and the adhesive of the valve

7). Downtime process, if a protection device, the recovery standby mode, we should take to protect return, find out the reason, when the spare ban stop button

8). Diesel generator in 30 seconds can't start when, should stop waiting for 1 to 2 minutes, again, allow start three times

9). If diesel generating sets long-term out of service (not spare, shall take measures to maintain)

10). Each running 250 hours, a new oil and oil filter core, fuel filter core, replace all kinds of filter down after cleaning shall not continue to use