1.real-time detection CO 2. 0~10VDC/4~20mA output 3. Modbus RS485 communication 4.CE-approval

Super CO transmitter for BAS and undergroung parking lots and garages

Sensors

Gas Sensor

Electrochemical carbon monoxide sensor

Sensor lifetime

Up to 5 years, replaceable

Warm up time

1hour (first time)   

Response Time

Within 60 seconds

Signal Update

1s

CO Measuring Range

0~500ppm(default)/0~100ppm/0~1000ppm  selectable

Accuracy

<1ppm+5%reading

Stability

±5% (over 900 days)

Temperature & Humidity Sensor (optional)

Temperature

Relative Humidity

Sensing element:

Band-gap-senor

Capacitive humidity sensor

Measuring range

-20°C~60°C

0 -100%RH

Accuracy

±0.5°C (20~40°C)

±4.0%RH (25°C, 15%-85%RH)

Display resolution

0.1°C

0.1%RH

Stability

±0.1°Cper year

±1%RH per year

Outputs

LCD Display (optional)

Display COmeasurement

or CO+ temperature& humidity measurements

Analog Output

1X0~10VDC or 4~20mA linear output

Analog Output Resolution

16Bit

Relay dry contact Output

Up to two dry-contact outputs

Max, switching current 3A (230VAC/30VDC), resistance Load

Modbus Interface

Modbus RS-485 with 19200bps(default), other rates selectable

in the order. 15KV antistatic protection

Electrical and General Items

Power Supply

24VAC/VDC                

Power Consumption

2.8W

Wiring Standard

Wire section area<1.5mm2

Working Condition

-10°C~60°C(14~140°F); 5~99%RH, non condensing

Storage Conditions

-10~60°C(14~140°F)/ 5~99%RH, non condensing

Net Weight

260g    

Manufacturing Process

ISO 9001 Certified

Housing and IP class

PC/ABS fireproof plastic material, protection class: IP30

Compliance

CE-EMC Approval

 

1.Design for real-time detection indoor carbon monoxide.

2.High accuracy humidity and temperature detection optional

3.LCD display carbon monoxide and optional temperature&RH measurement

4.Smart buttons for easy operation

5.Excellent electrochemical CO sensor with up to 5 years life time

6.Replaceable CO sensor

7.Provide 1X analog linear output (0~10VDC/4~20mA selectable) for the measurement

8.Providing up to two dry contact outputs with presetting the setpoint

9.Modbus RS485 communication interface optional

10.Provide two easy methods for calibration and setup alarm points by end users: infrared remote controller or a software via RS485

11.24VAC/VDC power supply

12.CE-Approval

8.24VAC/VDC power supply

Models Guide

TKG- CO- 1 X Y Z C- R–TH

1: wall mounted with the external sensor in an adown probe

X: analog output

         0: no analog output

         1: 1x0~10VDC linear output(default)

         2: 1X4~20mA linear output (default)

         3: 1X0~10VDC output and can be switch to 4~20mA (just for only one analog output)

Y:relay dry contact output

       0: no dry contact output

1: 1xdry contact output

2: 2xdry contact outputs

Z:Communication interface

       0: no communication

       1: Modbus RS485 interface

C:24VDC/VAC power supply

R: co range

  005: 0~500ppm (default)

001: 0~100ppm

   010: 0~1000ppm

-TH(option) temperature & RH detection and display

No –TH indicates without temperature & RH detection and display

-NL(option) No LCD display for the transmitter with the analog linear output or with the Modbus interface.

For example: TKG-CO-1101-001-TH indicates the CO detector with 1X0~10VDC linear output and Modbus interface. CO range:0~100ppm. It has temperature and humidity detection and display.

Super CO transmitter for BAS and undergroung parking lots and garages

Ads by Google


About Us | Contact Us | Help | Terms & Conditions
Hot Products: A | B | C | D | E | F | G | H | I | J | K | L | M | N | O | P | Q | R | S | T | U | V | W | X | Y | Z | 0-9
Copyright Notice @ 2008-2022 ECBAY Limited and/or its subsidiaries and licensors. All rights reserved.