Welcome to ECBAY
High accuracy Electronic meter
High accuracy Electronic meter

-Intelligent Electronic meter - LED or LCD - Support RS485 - Modularized design - High accuracy MOQ 1

AI-708H INDUSTRIAL Electronic meter

Main Features- Modularized structure and hardware compatible with other AI series instruments andmodules, which make it easy to maintain and quick delivered.

- Modularized and configurable inputs. The flow input can be 1-5V, 0-5V, 4-20mA orfrequency signal, and special user defined input specification is also available. Thetemperature input can be configured to Pt100 RTD, K, E, J type thermocouple,voltage, or current signal. The pressure input can be various voltage or currentsignal.- Abundant functions such as retransmission, high/low alarm of momentary flow,temperature and pressure, abnormal signal detecting, and communication withcomputer are available.- Square root/no square root selectable ,8-digits accumulation value and 4-digitsmomentary process value, small signal cut-out can be set at any range.- It has perfect temperature and pressure compensation used for general gas,saturated steam, overheat steam and liquid. The compensation calculation with themethod of table look-up has a high accuracy in the steam measurement application.Special function can be carried out by enhancing the compensation formula uponcustomers' demand.- As used as batch controller, it has 4-bit accumulator for control and 12-bitaccumulator for total sum individually.- With high precision current module installed, the totalizer can provide retransmissionwith 14 bit output resolution and 0.2%FS output precision.

Specification:

ModuleModule DescriptionsM1M2OUTPALMAUXCOMM
Nno module installed 
I0

Temperature input is thermocouple, RTD or mV signal input;

pressure or flow input is 0-5V or 1-5V voltage signal

     
J42 channel current inputs of 0-12mA, 4-20mA, 0-20mA etc.     
J52 channel two-wire transmitter provided 24VDC power supply.     
I2

Switch / frequency signal input interface for inputting external switch or

frequency signal, has a 12VDC power supply for external transducer.

     
I3

Single 0-5V/1-5V voltage signal input, with 24V/50mA power

supply for external transducer

     
I4

0-20/4-20 mA analogue input interface, providing a 24VDC/24mA

power supply for a two-wire transmitter

     

V5/V10/

V12/V24

Isolated 5V, 10V, 12V or 24V DC output with maximum current 50mA.

(use instrument’s internal 24V isolated power)

L1

1 relay contact output (Capacity: 2A/250VAC,

normal open terminal can absorb spark)

   
L21 relay contact (NO+NC) output. (small volume, 30VDC/1A, 250VAC/1A)   
L41 relay contact (NO+NC) output. (small volume, 30VDC/2A, 250VAC/2A)   
L52 relay contact(ON) outputs.(30VDC/1A,264C/1A)    
W1TRIAC no contact normal open output. (100~240VAC/0.2A)     
W2TRIAC no contact normal closed output. (100~240VAC/0.2A)     
GSSR voltage outputs (12VDC/30mA)     
X3

0~20/4~20mA linear current output module.

 (Use internal 12VDV power of the instrument)

     
X5

0~20/4~20mA linear current output module.

(With its own isolated power)

     
S

Photoelectric isolated RS485 communication module

(use instrument’s internal 12V isolated power)

     
S4

Photoelectric isolated RS485 communication module with its own

 photoelectric isolated power

     
R

RS232 communication interface (use instrument’s internal

12V isolated power)

     

Ordering code:

High accuracy Electronic meter

Ads by Google


About Us | Contact Us | Help | Terms & Conditions
Hot Products: A | B | C | D | E | F | G | H | I | J | K | L | M | N | O | P | Q | R | S | T | U | V | W | X | Y | Z | 0-9
Copyright Notice @ 2008-2022 ECBAY Limited and/or its subsidiaries and licensors. All rights reserved.