Specifications of Aluminium Shell Insensitive No. 8 Instantaneous Electric Detonator | |
Application | Suitable for blasting works without gas and coal-dust explosion risk. |
Item | Technical requirements |
Impedance | 2.4~3.5Ω (leg wire 2 meters long) 4.5~6.2Ω (leg wire 4 meters long) |
Safe current | Charge with 0.30A constant direct current for 5min., no explosion |
Lead plate test | Perforation diameter is no less than the external diameter of detonator |
Tensile property | Sustain 19.6N static tensile for 1 min., no visible damage and displacement. |
Series firing current | Charge 1.5A constant direct current to 20PCS in series, all explode. |
Marsh gas safety test | Passed inspection by the State designated agency |
Leg wire length (m) | 2.0 (Note: can be manufactured according to user requirement) |
Heat resistance | No explosion in 100°C environment for 4h |
Electrostatic sensitivity | When the capacity is 2,000pF, series resistor is 0Ω, and charging voltage greater than 10Kv, discharge to leg wire-detonator enclosure, no fire. |
Validity | 18 months |
Description | 1. This product is bridge silk heat type electric ignition industrial detonator. 2. This product may not be mixed with detonators of other factory. 3. Select best blasting network for use, and it is not allowed to pull the detonator body when it is taken out. 4. This product should be stored in the original package and kept in ventilated and dry warehouse with wood floor. |
Production date: | |
|
Aluminium Shell Insensitive No. 8 Instantaneous Electric Detonator