Unique door-free structure and big LCD screen All brands of standard IV sets are compatible CE,ISO
Fosmedic is a professional manufacturer and exporter for varies of syringe pumps, infusion pumps.The model of 600II infusion Pump has the following * Three kinds of modes: Rate Mode, Time Mode, Body Weight Mode.* Unique door free structure: Avoiding problems of pump stuck and fluid leakage.* Double CPU: Making the process of infusion safer and more reliable.* Accurate Injection: Precise control of the infusion rate and infusion volume. * Flow rate range: 1.0 ml/h-2000.0 ml/h.* Driven by step motor: No pulsating wave will be educed even during low-rate injection.* Alarm is given in the following situations: Infusion Completion, Occlusion, Low Battery, Air Bubble, Installation Error, Malfunction or Operation Error.* IV Set: All brands of standard IV sets are compatible.* KVO rate can be selectable according to concrete requirements from 1.0 ml/h to 5.0 ml/h. * Wireless Module Control: When used with 2000I or 900I, the infusion information will be transferred to the Infusion Supervision System in order to ensure the patients’ safety. * Big Color LCD.
Technical Parameters of 600II Infusion pump
Dimension | 120×140×195 mm |
Maximum weight | 2.0 kg |
Displayed information | RATE VOL.LIMIT ∑( accumulated infusion volume) Battery charge indicator AC power indicator Over OCCL. AIR BED No. |
Fuse | T 2AL 250V~ |
Maximum power consumption | 25VA, running more than 4 hours after being charged |
Infusion rate range | 1.0-2000 ml/h |
Bolus | Rate:≤1000.0 ml/h Bolus: 1000.0 ml/h |
Operation conditions | Environment temperature 5°C~40°C, air pressure 86kPa~106kPa, relative humidity ≤80% |
Electrical Safety | Comply with EN60601-1 for medical equipment and EN60601-2-24 |
Applicable infusion sets | All standard IV sets |
Accumulated infusion volume | 1.0~9999.0 ml |
Infusion accuracy | ±3% |
Alarm function | Over OCCL. Low battery IV line installation error AIR EMPTY Machine malfunction |
KVO rate | 1.0 ml/h-5.0 ml/h |
Selectable modes | Rate mode, Time mode, Weight mode |
Rate mode | 1.0~2000.0 ml/h |
Time mode | Volume limit: 0.1~999.9ml Time: 1~2000 minutes |
Body Weight mode | Drug limit: 1.0~999.9 mg, Volume limit: 0.1~999.9 ml. Weight: 0.1~300.0 kg, Dose: 0.1~9999.9 Selectable unit: mg/kg/h, ug/kg/min |
Battery | Rechargeable lithium polymer battery, 7.4V, 1600 mA |
Storage | Environment temperature-20~55°C, air pressure 50~106kPa, relative humidity ≤95% |
Infustion pump