1.CE, ISO9001.13485 certificated 2.Support 12 channel waves 3.Best quality and fast delivery 4.OEM service 5.12.1 inch
Discription:
1 12” color TFT display, support 12 channel waves, 6 parameters include: ECG/RESP, NIBP, SpO2, TEMP, dual IBP, CO2.
2 Unique human voice alarm.
3 Rich screen layouts: Standard, big font, trend table, NIBP trend, ECG full lead, OxyCRG, IOC Layout.
4 Powerful storage: maximum 720 hour graphic and tabular trends of all parameters, up to 10000 NIBP review, 200 alarm event review, 2 hours of all waveforms.
5 System software can be upgraded through network.
6 Standard configuration: ECG, RESP, TEMP, NIBP, SpO2
7 Optional: dual IBP, CO2, IoC, Recorder, VGA.
Screen Display
The display of may be color or monochrome liquid crystal display. The patient parameters, waveforms, alarm messages, bed number, date, system status and error messages can be reflected from the screen.
The screen is divided into three areas(See Figure 1/2):
message area;
waveform area;
parameter area.
Item No. | KD patient monitor003 | ||
Screen Size: | 12 inch | ||
ECG | Lead mode:I II III,AVR.VL.AVF.V | ||
GAIN:*0.25.*0.5.*1.*2(mm/mV) | |||
Hear rate: | 15-300 bpm(adult) | ||
15-350bpm(pediatric) | |||
Resolution:1bpm | |||
Accuracy:+-1% | |||
Bandwidth: Diagnostic:0.05-130Hz | |||
Monitor:0.5-40Hz | |||
Surgery:1-20Hz | |||
Sweep speed:12.5mms,25mm/s,50mm/s | |||
Pacemaker rejection:Yes | |||
ST measurement Range:-2.0+-2.0mv | |||
Accuracy:+-0.02mv or +-10% which is greater | |||
Spo2 | Measure range:0-100% | ||
Resolution:1% | |||
Accuracy:+-2% | |||
Resolution:1bpm | |||
Accuracy:+-3bpm | |||
NIBP | Work mode: manual,automatic,continuous | ||
Unit: mmHg,Kpa | |||
Measure range: | adult: SYS:40-280mmhg | ||
DIA:10-220mmhg | |||
MEAN:20-240mmhg | |||
Pediatric:SYS:40-220mmhg | |||
DIA:10-160mmhg | |||
MEAN:20-170mmhg | |||
Neonatal:SYS:40-135mmhg | |||
DIA:10-100mmhg | |||
MEAN:20-100mmhg | |||
Resolution:1mmhg | |||
Accuracy: max mean error:+-5mmhg; max standard deviation:8mmhg | |||
Overpressure protection:0-300mmhg | |||
Degree of protection:BF.CF | |||
RESP | Measure range: | Adult:0-120rpm | |
pediatric.neonatal 0-150rpm | |||
Resolution:1 rpm | |||
Accuracy:+-2% | |||
TEMP | Channels:2 | ||
Measure range:0-50°c | |||
Resolution:0.1°c | |||
Accuracy:+-0.1°c(25-45c°) | |||
IPM (optional) | Channels:2 | ||
Measure range:-50-360mmhg | |||
ccuracy:+-2%or +-1mmhg which is greater | |||
Co2 (optional) | Measure range:0%-13% | ||
Resolution:1mmhg | |||
Accuracy:+-12mmhg@<5.0%co2 (at ATPS) | |||
Resp:3-15rpm | |||
Ioc(optional) | EEG sensitivity:+-475uV | ||
CMRR:>100DB | |||
Input impedance: >50Mohm | |||
IoC: 0-100 | |||
ESR: 0-100% | |||
EMG: 0-100 | |||
Recorder optinal | Width:48mm | ||
Speed:25-50mm | |||
Channels:2 |