Welcome to ECBAY
CE Certificate Anesthesia Machine( ACM619)
CE Certificate Anesthesia Machine( ACM619)

Electric PEEP, VCV,PCV,PSV,PRVC,CE quality guarantee, export to European market,very high price and performance ratio.

 

 

 

 

Anesthesia Machine

Supply gas pressure                                       280kPa-600kPa

evaporator concentration                                0.2%~5%

Oxygen concentration                                     ≥21%

O2 flush                                                         25L/min~75L/min

Gas pressure alarm (electromotion)               0.185~0.22MPa

 

ANESTHESIA VENTILATOR

The main characters

Application                    Adult,Child and neonate

Driven mode                 Pneumatically driven and electrically controlled, time switch

Ventilation modes         VC-IPPV,VC-SIPPV,VC-SIGH,VC-SIMV,PC-IPPV,PC-SIMV,PC-SIPPV,VC-PSV,PC-PSV, PR-IPPV,PR-SIPPV, PR-SIMV,PR-PSV,Manual

Respiratory rate            1bpm~100bpm, tolerance ±15%

Tidal volume                 working range 20mL~1600mL ,continuously adjustable.

I/E ratio                          1/0.3~1/8

Triggering sensitivity     0.0kPa~2.0 kPa,tolerance±0.1kPa

Waveform                      Double waveforms displaying for pressure-time and flow-time (optional: volume-time, CO2-time, pressure volume loop, flow volume loop)

Tih                                 0-60% inspiratory time

Inspiratory pressure     0.3kPa~6.0kPa,tolerance±0.1kPa

ps/ramp                        0.02s~2.00s

Supply pressure          0.3kPa~6.0 kPa,tolerance±0.1kPa

Triggering flowrate      OFF,0.1LPM~20LPM,tolerance±0.5LPM

ELECTRIC PEEP        OFF,0.3kPa~3.0 kPa,tolerance±0.1kPa

PS end flow                  1%~60% maximal flow

triggering window          20%~95%

Pressure Limit               0.9kPa~7.9 kPa

 

Monitoring parameters

Respiratory rate, I/E ratio, breath holding time, Tidal volume, Minute volume, Ppeak, Average Pressure, minimum pressure, PEEP, FIO2 concentration,

Optional (FICO2 concentration, ETCO2 concentration, BIS), compliance.

 

Alarms

Airway pressure, Tidal volume, Minute volume, Oxygen concentration, Power failure, Apnea, Flow sensor failure, Respiratory rate, Flow sensor failure, Optional(ETCO2 concentration,FICO2 concentration), Lower gas pressure, sustained pressure, complete pipeline, PEEP, Silence time for alarm ≤120s.

 

ANESTHESIAMACHINE Flowmeter

O2(two tubes)          0.05~1L/min ,1.0~10L/min

N2O (two tubes)       0.05~1L/min,1.0~10L/min

Air (two tubes)          0.05~1L/min,1.0~10L/min

ORC device             The proportion between O2 and N2O can be continuously adjustable to assure the O2 concentration above21%.

 

Other function

Altitude compensation, O2 compensation, N2O compensation, big screen display, alarm volume adjustment, Start self-test, compliance compensation, leakage compensation

 

 Power                                                                                    less than50VA

Machine noise                                                                       £65db

Input power supply                                                                AC 110/220V input

Output power supply                                                              DC 24V output, tolerance±1% 

Power supply Interface                                                          RS485

Anti-jamming requirement        it can resist the power conduct and radiation of other equipments

Language                                                                                Spanish, English