Welcome to ECBAY
All Kinds of IV Sets Infusion Pump IP300
All Kinds of IV Sets Infusion Pump IP300

High accuracy infusion pump Available for all kinds of IV sets Can used for neonatal Flow rate from 1ml/h to 1300ml/h CE,ISO

Infusion Pump IP300

High accuracy infusion pumpAvailable for all kinds of IV setsCan used for neonatalFlow rate from 1ml/h to 1300ml/hCE,ISO

Specifications

1. Patient type: Adult, pediatric and neonatal

2. Driven mode: Electrical motor driving

3. Applicable for all IV sets

4. Flow rate: 1mL/h~1300mL/h

5. Preset volume range: 1mL~9999mL

6. Accumulated infusion volume display range: 1mL~9999mL

7. KVO (keep vein open):

     1mL/h ≤flow rate ≤5mL/h, KVO rate is OFF

     5mL/h <flow rate <50mL/h, KVO rate is 1mL/h

     50mL/h ≤flow rate <300mL/h, KVO rate is 3mL/h

     300mL/h ≤flow rate ≤1300mL/h, KVO rate is 5mL/h

8. Flow rate accuracy:

     ±5% (specified IV set)

     ±10% after calibration (ordinary IV set)

9. Bolus rate: Five patterns: 

     600mL/h, 700mL/h, 800mL/h, 900mL/h, 1000mL/h

10. Air sensor sensitivity: ≥0.015mL

11. Occlusion detector sensitivity: Adjustable in 5 levels

       0.04MPa ±30%

       0.06MPa ±30%

       0.09MPa ±30%

       0.12MPa ±30%

       0.15MPa ±30%

12. Alarms: Internal fault, Low battery voltage, AC failure, Door open, 

Occlusion, Air in line, Empty, Heat malfunction, Interrruption of the AC power supply

13. Alarm volume: ≥65dB (A)

14. Pump running noise: ≤50dB (A)

Power Supply & Battery

Inner battery: Ni-MH 9.6V AA 1500mAh, Operating ≥4 hours after full charge

Power source: AC 100~240V, 50/60Hz;       DC 15V

Power consumption: ≤15VA

Classification & Safety

Classification: Class I; Internal power supply; type BF; IPX1

Electric security: IEC 60601-1

Security: IEC 60601-2-24

EMC: IEC 60601-1-2

Storage & Operation Condition

Storage:

Temperature: -20~55°c

Relative humidity: ≤93%

Atmospheric pressure: 50KPa~106KPa

No exposed to corrosive gases, stored in well ventilated room

Operation:

Temperature: 5~40°c

Relative humidity: 20~90%

Atmospheric pressure: 70KPa~106KPa

Altitude: 4000m below

Dimension & Weight

Dimension: H245xD180xW170mm

Weight: ≤3kg

Accessories & Document

Power calbe

User Manual

OptionalHeating function

Trolley

All Kinds of IV Sets Infusion Pump IP300

Ads by Google


About Us | Contact Us | Help | Terms & Conditions
Hot Products: A | B | C | D | E | F | G | H | I | J | K | L | M | N | O | P | Q | R | S | T | U | V | W | X | Y | Z | 0-9
Copyright Notice @ 2008-2022 ECBAY Limited and/or its subsidiaries and licensors. All rights reserved.