Welcome to ECBAY
Desktop Pulse Oximeter(BW2A)
Desktop Pulse Oximeter(BW2A)

1)Portable,Compact,LED Display 2)SPO2,Pulse Rate,Alarm 3)Internal Rechargeable Battery 4)For Adult,Pediatric,Neonate/baby

Desktop Pulse Oximeter(BW2A)

Features:

*Bright, Easy-to-Read Large LED Display

*Durable, Compact and Lightweight

*Long-life Internal Rechargeable Battery for

*Uninterrupted Monitoring

*Accurate and Reliable During Low Perfusion and Motion

*Audible/Visual Three Level Alarms with Alarm Volume Control

*72-hour Data Memory Allowing On-screen Viewing of SpO2 and Pulse Rate Trends

* Suitable for Adult, Pediatric and Neonate

 

Technical Specs

SpO2 Accuracy:

No Motion:

Adults, Pediatrics: 70~100% ±2%    0~69% unspecified

Neonates:               70~100% ±3%    0~69% unspecified

 

Motion:

Adults, Pediatrics: 70~100% ±3%    0~69% unspecified

Neonates:               70~100% ±4%    0~69% unspecified

 

Low Perfusion:

Adults, Pediatrics: 70~100% ±3%    0~69% unspecified

Neonates:               70~100% ±4%    0~69% unspecified

 

Pulse Rate Accuracy

No Motion:

Adults, Pediatrics, Neonates: ±3%

 

Motion:

Adults, Pediatrics, Neonates: ±5%

Low Perfusion:

Adults, Pediatrics, Neonates: ±5%

 

Displays and Indicators

SpO2, Pulse Rate and Pulse Strength Bar

Pulse Search Indicator

Low Perfusion and Motion Warning Indicator

Alarm Silence Indicator

AC Power and Battery Charge Indicator

Low Battery Warning Indicator

Sensor Disconnect and Sensor off Warning Indicator

Alarm

 

Audible/Visual Alarms for High/Low SpO2 and PR

Audible/Visual Alarms for Low-Battery

Alarm Limits Adjustable

Alarm Volume Adjustable

Pulse Search Indicator

Alarm Silence Interval:30,60,90and120sec and OFF

Low Perfusion and Motion Warning Indicator

Sensor Disconnect Alarm

Sensor off Alarm

 

Performance Measurement Range

SpO2:0~100%

Pulse Rate: 20bpm~250bpm

Environment

Opreation Temperature: 5~40°C   41~104°F

Humidity: ≤80%

Altitude: -390~5,000m(-1,280~16,404ft)

Transport/Storage Temperature:

-20~+70°C (-4°F~158°F)

Humidity: ≤95%

 

Output

RS-232 Serial Port for Digital Output

Nurse Call Function

 

Electrical Instrument

Power Requirements:

100~240VAC, 50/60Hz, 20VA

Fuse Rating: 1.0A

 

Battery

Internal Battery: 12V 3.6Ah

Battery Capacity: ≥ 24 hours

 

Physical Characteristics

Dimensions:

264mm(W) x 95mm(H) x 172mm(D)

[10.39in(W) x 3.74in(H) x 6.77in(D)

Net Weight: 2.5kg/5.5ib

Gross Weight: 3.5kg/7.7ib

 

Compliance

SpO2: ISO9919:2005

Safety Standards: En60601-1: 1990+A1: 1993+A2: 1995+A13: 1996 Type BF-Applied IPX1 Approved

Alarm: IEC60601-1-1-8: 2005

EMC:EN60601-1-2: 2001, Group1 Class A

Environment: WEEE(2002/96/EC)

 

Optional Part

Thermal Array Recorder to print Graphical and Tabular Trend

Desktop Pulse Oximeter(BW2A)

Ads by Google


About Us | Contact Us | Help | Terms & Conditions
Hot Products: A | B | C | D | E | F | G | H | I | J | K | L | M | N | O | P | Q | R | S | T | U | V | W | X | Y | Z | 0-9
Copyright Notice @ 2008-2022 ECBAY Limited and/or its subsidiaries and licensors. All rights reserved.