Welcome to ECBAY
iPAD NF1200 (Semi & Fully Available) Intelligent Public Access Defibrillator
iPAD NF1200 (Semi & Fully Available) Intelligent Public Access Defibrillator

Semi-Automatical External Defibrillator iPAD NF1200 (Semi & Fully Available) Intelligent Public Access Defibrillator

Semi-Automatical External DefibrillatoriPAD NF1200 (Semi & Fully Available) Intelligent Public Access Defibrillator

Product overview:

The i-PAD NF1200 is a semi-automated external defibrillator (also known as an AED). The i-PAD NF1200 is designed for minimally trained individuals. It provides simple and direct voice prompts and instructions for straightforward rescue operation. It is lightweight and battery powered for maximum portability. The i-PAD NF1200 is intended to treat Ventricular Fibrillation (VF) and Fast Ventricular Tachycardia. These two conditions are the most common causes of sudden cardiac arrest (SCA). In SCA, the heart of the victim suddenly stops pumping. This condition may occur suddenly to any age group without warning. The only effective treatment for SCA is the application of a defibrillating shock.

 
 

How to use i-PAD NF1200

 

Key features:

Product specification:

You can check it in the PDF specification sheet.

Physical

Size

2.75 in high X 8.66 in wide X 10.23 in deep (70mm high X 220 mm wide X 260 mm deep)

Weight

Approximately 4.84 lbs (2.2 kg) with battery pack installed

Environmental

Operating Conditions

Temperature

32 F to110 F(0C to 43 C)

Humidity

5 % to 95 % (non-condensing)

Storage Conditions

Temperature

32F to 110 F (0 C to 43 C)

Humidity

5 % to 95 % (non-condensing)

Shock/Drop/Abuse Tolerance

Meets IEC 60601-1 clause 21 (Mechanical Strength)

Vibration

Meets EN1789 random and swept sine, road ambulance specification in operating and standby states.

Sealing

IEC 60529: IP54

ESD

Meets IEC 61000-4-2:2001

EMI (Radiated)

Meets IEC 60601-1-2 limits, method EN 55011:1998+ A1:1999 +A2:2002, Group 1, Class B

EMI (Immunity)

Meets IEC 60601-1-2 limits, method EN 61000-4-3: 2001 Level 3 (10V/m 80MHz to 2500MHz)

Defibrillator

Operating Mode

Semi-automated

Waveform

e-cube biphasic (Truncated exponential type); impedance compensated

Energy

200 Joules nominal into a 50 load

Shock Energy Accuracy

Within ±3% (150J into 50)

Charge Control

Automatic by Software (Arrhythmia Detection System and Charging Control)

Charge time from “Shock Advised”

< 14 seconds, typical

Shock to Shock cycle time

< 15 seconds, typical, including analysis

Charge complete indicator

* Text prompt (PRESS THE FLASHING ORANGE BUTTON, NOW)* flashing backlight of SHOCK button* beep from the beeper

Disarm

Once charged, the NF1200 disarms if:* Patient’s heart rhythm changes to non-shockable rhythm, or* The SHOCK button is not pressed within 15 seconds after the NF1200 is armed, or* The ON/OFF button is pressed to turn OFF the NF1200, or* The defibrillator pads are removed from the patient or the pads connector is disconnected from the NF1200

Defibrillator, continued

Shock Delivery

Shock is delivered if the SHOCK button is pressed while the NF1200 is armed.

Shock Delivery Vector

Via adult defibrillator pads in the anterior-anterior (Lead II) position or via Reduced-energy pediatric pads in the anterior-posterior position.

Patient Isolation

Type BF

ECG Acquisition

Acquired ECG Lead

Lead II

Frequency Response

1 Hz to 30 Hz EMS Mode0.3 Hz to 40 Hz Monitoring Mode

ECG Analysis System

Function

Determines the impedance of the patient and evaluates the ECG of the patient to determine whether it is shockable or non shockable

Impedance Range

25 to 175

Shockable Rhythms

Ventricular Fibrillation or Fast Ventricular Tachycardia

Non Shockable Rhythms

ECG rhythms other than Ventricular Fibrillation or Fast Ventricular Tachycardia

Sensitivity & Specificity:

Meets AAMI DF39 guidelines

Controls, Indicators, and Prompts

Controls

Power On/Off Button, i-Button, Shock Button

Indicators

State LED, Graphical Rescue Guide LED

Audio Speaker

Provides voice prompts

Beeper

Provides various audible indications

Low Battery Detection

Automatic during daily testing and Power ON and runtime testing

Low Battery Indicator

State LED and Voice Prompt

Prompts

Voice prompts guide the user throughout a rescue operation

Self-Tests

Automatic

* Power On Self-Test / Run Time Self-Test* daily / weekly/ monthly

User Initiated

Battery Insertion Test

Battery Pack

Battery Type

12 Volt DC, 4.2 Ah, lithium manganese dioxide, disposable long-life primary cell.

Capacity

Minimum 200 shocks or 4 hours of operating time.

Temperature Range

-40 °F to 140 °F (-40 °C to 60 °C)

Defibrillator Pads (CUA0512F)

Type

self-adhesive, disposable, non-polarized defibrillation pads

Adult Pads

Defibrillation pads for patients 8 years of age and older or 55 lbs. (25 kg) and over.

Surface Area

Adult : 110cm2 each

Cable Length

1.5m

Data Recording and Transmission

Infrared

Wireless transmission of event data to PC through IrDA port.

Data Stored

First 40 minutes of ECG and the entire incident’s events and analysis decisions.

Accessories:

Standard Package

- Device

- Disposable Defi pads

- Li-ion disposable battery

- User guide

- Quick reference card

Optional Accessories

- Carrying case

- Adaptor for battery charging

- Rechargeable Battery Pack

- IrDA Connector for data communication

- Software for data managing with Key File

- Wall Bracket

- Wall Cabinet (Small) with Alarm (Included AED Sign)

- Pediatric pads

Pictures:

iPAD NF1200 (Semi & Fully Available) Intelligent Public Access Defibrillator

Ads by Google


About Us | Contact Us | Help | Terms & Conditions
Hot Products: A | B | C | D | E | F | G | H | I | J | K | L | M | N | O | P | Q | R | S | T | U | V | W | X | Y | Z | 0-9
Copyright Notice @ 2008-2022 ECBAY Limited and/or its subsidiaries and licensors. All rights reserved.