Welcome to ECBAY
ABC cable
ABC cable

ABC cable: 1. CE, ISO, SGS, SANKOP Certificate 2. Exported to many countries 3. Favourable Offer

Detailed Product Description

abc cable/overhead cable/aerial cable/can be made according to the BS, IEC, ASIN, DIN, JIS, CSA standards. Etc.1KV, 10KV, et

abc cable/overhead cable/aerial cable/can be made according to the BS, IEC, ASIN, DIN, JIS, CSA standards. Etc.1KV, 10KV, e

Aerial Bundle Cable (ABC cable), 0.6/1KV, XLPE insulation, Aluminum Conductor

Product Description

1. Application of Service Drop Cable: Service Drop Cable(ABC CABLE) are mainly used for electric power tranmission, rebuiding of urban and forest regions. They can improves safety and reliance of electrified wire netting. 2. Type of Service Drop Cable: Service Drop Cable(ABC CABLE) covers mainly three types: Duplex Service Drop Triplex Service Drop Quadruplex Service Drop The cable can be produced whose construction is phase conductor with neutral bare conductor or phase conductor with insulated neutral conductor, etc. And we can still produce the cables according to the request of customers. 3. Detaild Introduction of Service Drop Cable 3.1 Duplex Service Drop Applications To supply 120 volt aerial service for temporary service at construction sites, outdoor or street lighting. For service at 600 volts or lower at a conductor temperature of 75 maximum. Construction Concentic strand or cmpressed 1350-H19 conductor, polyethylene or cross linked polyethylene insulation, concentric strand AAC, ACSR, or 6201 alloy nertral messenger. 3.2 Triplex Service Drop Applications To supply power from the ulility`s lines to the consumer`s weatherhead. For service at 600 volts or less(phase to phase ) at a conductor temperature of 75 maximum for PE insulation or 90 maximum for XLPE insulation. Construction Concentic strand or cmpressed 1350-H19 conductor, polyethylene or cross linked polyethylene insulation, concentric strand AAC, ACSR, or 6201 alloy nertral messenger. 3.3 Quadruplex Service Drop Applications Used to supply 3 phase power, usually from a pole-mounted transformer to the use`s servic head where connection to the service entance cable is made. To be used at voltages of 600 volts or less phase to phase and at conductor temperature not to exceed 75 for PE insulated conductors or 90 for XLPE insulated conductors. Construction Conductors are concentrically standed, compressed 1350-H19 aluminium. Insulated with either polyethylene or XLPE. Neutral messengers aer concentrically stranded 6210 AAAC, AAC or ACSR

Standards: 1. B-230 Aluminum Wire, 1350-H19 for Electrical Purposes. 2. B-231 Aluminum Conductors, Concentric-Lay-Stranded. 3. B-232 Aluminum Conductors, Concentric-Lay-Stranded, Coated Steel Reinforced (ACSR). 4. B-399 Concentric-Lay_Stranded 6201-T81 Aluminum Alloy Conductors. 5. B498 Zinc-Coated Steel Core Wire for Aluminum Conductors, Steel Reinforced (ACSR). 6. Duplex Service Drop cable meets or exceeds all applicable requirements of ANSI/ICEA S-76-474

           

Update Date:2011-5-13 03:51:14

ABC cable

Ads by Google


About Us | Contact Us | Help | Terms & Conditions
Hot Products: A | B | C | D | E | F | G | H | I | J | K | L | M | N | O | P | Q | R | S | T | U | V | W | X | Y | Z | 0-9
Copyright Notice @ 2008-2022 ECBAY Limited and/or its subsidiaries and licensors. All rights reserved.