Welcome to ECBAY
air cooled V-Twins engine power portable small silent diesel generator 10kw (8KW 10KW 12KW )
air cooled V-Twins engine power portable small silent diesel generator 10kw (8KW 10KW 12KW )

small silent diesel generator 10kw 1)air cooled,electrical 2)3P4W 220/380V 3)ATS,battery small silent Diesel generator 10kw

small silent diesel generator 10kw

air cooled portable silent diesel generator set 10kw .V-Twin  type 15/18hp diesel engine powerful,electric start,8/10/12/15/16kw,open or silent type, single phase or three phase

open frame type or silent type 10kw diesel generator set Specifications

1.Hot sale silent air-cooled 10kw diesel generator 2.Diesel generator 1.5kw-12kw 3.ISO,CE approved supplier

Diesel generator  1.5kw-12kw

Type:soundproof,open,rainproof and mobile.

-stable output,lightest and smallest among the diesel generators with same power -auto protection system military standard

MODELRated outputDescription
8GF-LDE9KVA/50HZ   10KVA/60HZ8KW single phase,E-start,open frame
8GF-LDE310KVA/50HZ   11KVA/60HZ8KW three phase,E-start,silent type
9GF-LDE9.5KVA/50HZ 10KVA/60HZ9KW single phase,E-start,open frame
9GF-LDE311KVA/50HZ 12KVA/60HZ9KW three phase,E-start,silent type
10GF-LDE11.2KVA/50HZ 12KVA/60HZ10KW single phase,E-start,open frame
10GF-LDE313KVA/50HZ 14KVA/60HZ10KW three phase,E-start,silent type
12GF-LDE12.5KVA/50HZ 13.3KVA/60HZ12KW single phase,E-start,open frame
12GF-LDE315KVA/50HZ 15.5KVA/60HZ12KW three phase,E-start,silent type

air cooled V-Twin diesel engine power silent 10KW generator set detailed specs as following:

10kw generator set Model10GF-LDE10GF-LDE312GF-LDE12GF-LDE3
Rated frequency (Hz)50       6050       6050       6050       60
Rated output power (kVA)9       1010       1110       1111       12
Max. power (Kva)10       1111       1211       1212      13
Rated voltage (V)230     240400/230  416/240230     240400/230 416/240
Rated current (A)39.1   41.714.4     15.343.5   45.815.9     16.7
Phase No.SingleThreeSingleThree
Power factor0.9 (lag)0.8 (lag)0.9 (lag)0.8 (lag)
InsulationF
Pole No.2
Exciting wayBrush, exciting-self voltage-constant (with AVR)
Panel typeIntelligent
Output socketSingle-phase socket, wiring terminalThree-phase socket, single-phase socketSingle-phase socket, wiring terminalThree-phase socket, single-phase socket
DC12V output12V, 8.3A
Dimensions L×W×H mm1040×660×740
Net weight Kg245
Noise (7m)dB(A)70
Structure typeFully closed
Engine model2V822V84
TypeV-twin, two-cylinder, four-stroke, DI
Cylinder No. –bore ×stroke (mm)2-86×702-86×72
Total displacement (ml)812836
Compressed ratio20:01
Cooling wayAir-cooled
Lubricating wayPressure & splashing
Starting wayElectric
Fuel used0 # (summer ) -10 # (winter) -35 # (cold winter) light diesel
Oil usedSAE10W30 (CD grade above)
Lubricating oil capacity (L)1.7
Starting motor capacity (V-kW)12V  1.4kW
Dynamo capacity (V-A)12V     8.3A
Battery capacity (V-Ah)12V     45AH
Fuel consumption under full loading  L/H3.0     3.73.0    3.73.5     4.03.5      4.0
10KW Diesel generator set Fuel tank capacity  L21
10kw diesel generator set Continuous running time  H7.0     5.77.0    5.76.0     5.36.0     5.3

 The lightest and smallest among the gensets with same outpout

Full automatic generator protection system

Special dual protection system

Unique unloading system for stopping the generator

Steady frequency-governing ratio ≤ 3%, complying with military standard

Automatic Voltage Regulation for maintaining steady voltage

Automatic transfer switching,remote monitoring, to realize guardless by human

Low noise,only 70dB/7m

New patent design,low inner housing temperature,stable output and good reliability 

10kw diesel generator set Features:

1. Comparing other generators with same output, it is of compact structure (1100*660*740mm), light weight (248kg)and reliable performance.

2. Adopting the technique of new patented design structure

Our company has adopted the technique of new-patented design structure to separate fully cold & heat wind passages in inner housing. It makes the generator output be no power drop for long-period operation.

The wind passage with special labyrinth design makes the generator be of lower noise.

3. Application of intelligent control panel

Our company has adopted new-type intelligent control panel, which facilitate the operation. The operator can know the real working condition of the generator from panel reading. There are more than ten protections of the generator in the panel, such as protections of frequency, voltage, current, low oil pressure, low fuel level, and electric fan adjusting the temperature automatically when inner-housing temperature over 60, and automatic unload before engine stopped each time etc. The diesel/water separator can ensure the fuel quality.

4. Application of automatic shifting switch (ATS)

Our company can fit ATS based on customer requirement, which can make the generator be automatic operation without the operator on the spot. When city power net breaks down, ATS can deliver the signal in shortest time to the generator for starting. When city power net is recovered, ATS can shift the power from the generator to city power net and the generator will be automatically stopped later.

5. Application of new-generation intelligent AVR

adopted new-generation intelligent AVR (automatic voltage-constant) to make the output voltage be steady.

pictures of portable silent 10kw diesel generator set

air cooled V-Twins engine power portable small silent diesel generator 10kw (8KW 10KW 12KW )

Ads by Google


About Us | Contact Us | Help | Terms & Conditions
Hot Products: A | B | C | D | E | F | G | H | I | J | K | L | M | N | O | P | Q | R | S | T | U | V | W | X | Y | Z | 0-9
Copyright Notice @ 2008-2022 ECBAY Limited and/or its subsidiaries and licensors. All rights reserved.