Welcome to ECBAY
IAC-380-200KW AC Load Unit
IAC-380-200KW AC Load Unit

Intelligent AC load unit 1. support AC 1phase/3 phase 2. rated power: 200KW 3. power step: 1KW 4. PC software & excel report

For the varies of generators, gensets and UPS, the output power and loading capability test are very crucial in the acceptance inspection, performance analysis, replacing judgments of power supply devices. But for most of device ascendants, it is a tough issue in operating the tester and analyzing the results. Considered all difficulties for the users, IAC-380 series intelligent AC dummy load provide a scientific and convenient measure to check the power supply devices. Applying intelligent control technologies, IAC-380 series fulfill loading discharging and parameter checking simultaneously. After the test, PC analysis software can create data report automatically. It is widely available for high power UPS, inverters, diesel generators in many industries like telecommunication stations, power sectors, airport etc.

Function Features:

Steady-state test: automatically detect 3-phase voltage, current, active power, inactive power, apparent power, power factor, frequency, run time, total energy and so on. Transient-state test: according the presetted power values, IAC-380 series can create a loading dips and drops, automatically detect the maximum and minimum values of each phase voltage, current and frequency in the dips and drops, and calculate the power & power factor in each phase. Setting test: according the presetted values, IAC-380 series can increase the load in steps by proportion up to the maximum power, and then decrease the load in steps. In this process, IAC-380 series will automatically detect the maximum and minimum values of voltage, current and frequency, 3-phase power & power factor in each steps. Fluctuation test: according the presetted values, IAC-380 series can increase the load in steps by proportion up to the maximum power, and automatically detect the maximum and minimum values of voltage, current and frequency, 3-phase power & power factor. Harmonics analysis: IAC-380 series can analyze the current, voltage 2-20 THD (total harmonic distortion) in each phases. IAC-380 series can support both 3-phase and 1-phase power test. The most powerful unit can provide 100KW. Parallel operation: for the requirement of some high power test, IAC-380 series can co-work in parallel perfectly. Phase sequence test: automatically detect the phase sequence of the generator & UPS. Adopting 5.7 inch colorful touching LCD: English interface make the operation convenient and directviewing. without PC and other recording device, the internal data storage memory of IAC-380 series can save 250 groups of data The user can choose browsing the real-time data in the process of testing by the software shown by laptop screen, or download the data to PC by RS-485 or USB after the testing. Applying overheating precaution function, IAC-380 series can cut off the load, terminate the discharge and alarm the user automatically when overheating happen. IAC-380 series provide the emergent stop switch, the users can terminate the test manually by single button. Short circuit protection function, guarantee the test safe and stable.

 Typical Applications:

 Test the output power and loading capability of the diesel generators 1. In the acceptance inspection of new diesel generator, the relevant department have to check whether the new devices fulfill the actual requirement. 2. After the installation of noise reduction devices like a muffler to the diesel generator, the  loading capability must be test again. 3. After the overhaul of diesel generator, it is necessary to test the situation like output power and loading capability 4. For the routine test & maintenance, it is essential to test the output power and loading capability of the diesel generators at least 15-30 minutes each 6 months. 5. For the replace judgment for the old diesel generator

Test the output power and loading capability of UPS devices 1. In the acceptance inspection of new UPS devices, the relevant department have to check whether the new devices fulfill the actual requirement. 2. For the routine test & maintenance of the UPS devices, it is essential to make a discharging test each year. 3. For the replace judgment for the old UPS devices. 

Test the output power and loading capability of AC voltage regulator, inverter, switching power supply.

Specifications:

Type

IAC-380-200KW

Loading Power(constant adjustable)

0~200KW

Power Factor

Test range: 0.001~1.000          Resolution: 0.001    Accuracy:0.5%

Harmonics(THD)

Test range: 2~50 harmonics(THD)  Resolution: 0.01%    Accuracy: 1%

Voltage

Test range: AC 0~450V            Resolution: 0.1V     Accuracy: 0.5%

Frequency

Test range: 45~65 Hz              Resolution: 0.01Hz   Accuracy: 0.2%

Current Display

Resolution: 0.1A,Accuracy: 0.5%

Input Voltage

AC 3 Phase 380V / AC 1 Phase 220V

Discharging Time

0~99 hours 59 minutes, constant adjustable

Cooling Mode

Air cooling

PC Communication

RS485, USB data port, USB disk port

Internal Memory

Internal storage device can save 250 groups of data, and support download data by PC or USB disk

Display Mode

5.7 inch colorful touching LCD, English operating menu

Display Items

3 Phase voltage, current, frequency, temperature, power, total energy, run time

Analysis Software

English version analysis PC software

Power Source

220V±10% or Power from the tested devices

Note

Support customized design and manufacture for some special demands

IAC-380-200KW AC Load Unit

Ads by Google


About Us | Contact Us | Help | Terms & Conditions
Hot Products: A | B | C | D | E | F | G | H | I | J | K | L | M | N | O | P | Q | R | S | T | U | V | W | X | Y | Z | 0-9
Copyright Notice @ 2008-2022 ECBAY Limited and/or its subsidiaries and licensors. All rights reserved.