Welcome to ECBAY
fiber & mica compound insulated fire-proof signal cable
fiber & mica compound insulated fire-proof signal cable

cables are designed for railway signalling systems nominal voltage to earth below 1100 volts

Application

The cables are designed for railway signalling systems. The cables are suitable for use in d.c. circuits where the nominal voltage to earth does not exceed 1100 volts and are suitable for installation in ducts.

Standards

NR/PS/SIG/00005(formerly RT/E/PS/00005)

Construction

ConductorsTinned stranded copper, class 2 according to IEC 60228 & BS 6360.

InsulationLSZH crosslinked.

Core WrappingPlastic tape(s) with overlapping.

SheathLSZH (for types A2 & A3 only).

Electrical Characteristics at 20°C

Nominal Conductor Cross Sectionmm²0.751.15
Maximum Conductor DC ResistanceΩ/km24.817.3
Voltage RatingKV0.65/1.1
Nominal Insulation Thicknessmm0.850.85

Mechanical and Thermal Properties

Minimum Bending Radius: 6×OD (static); 15×OD (dynamic)Temperature Range: -25°C to +85°C (during operation); -10°C to +85°C (during installation)

Dimensions And Weight

Cable CodeNo. of cores& NominalConductor CrossSectional AreaNo.×mm²No. & NominalDiameter of StrandsNo/mmNominal SheathThicknessmmOverall DiameterMin/MaxmmNominalWeightkg/km
Type A1(without sheath)
RS/A1-H-1G0.75(BL)1x0.75(blue)7/0.37-2.7/3.216
RS/A1-H-1G0.75(BR)1x0.75(brown)7/0.37-2.7/3.216
RS/A1-H-1G0.75(RD)1x0.75(red)7/0.37-2.7/3.216
RS/A1-H-1G0.75(OR)1x0.75(orange)7/0.37-2.7/3.216

RS/A1-H-1G0.75(GR)

1x0.75(green)

7/0.37

-

2.7/3.2

16

RS/A1-H-1G0.75(VI)

1x0.75(violet)

7/0.37

-

2.7/3.2

16

RS/A1-H-1G0.75

1x0.75(black)

7/0.37

-

2.7/3.2

16

RS/A1-H-1G1.15

1x1.15(black)

16/0.30

-

2.9/3.6

21

Type A2(with sheath)

RS/A2-3GH-1G0.75

1x0.75

7/0.37

0.7

4.0/5.0

30

RS/A2-3GH-1G1.15

1x1.15

16/0.30

0.7

4.3/5.3

35

Type A3(with sheath)

RS/A3-3GH-2G0.75

2x0.75

7/0.37

0.9

6.7/8.8

67

RS/A3-3GH-4G0.75

4x0.75

7/0.37

1.0

8.0/10.4

108

RS/A3-3GH-6G0.75

6x0.75

7/0.37

1.1

9.7/12.5

160

RS/A3-3GH-10G0.75

10x0.75

7/0.37

1.2

12.6/16.1

259

RS/A3-3GH-14G0.75

14x0.75

7/0.37

1.3

13.8/17.7

495

RS/A3-3GH-36G0.75

36x0.75

7/0.37

1.6

21.6/26.9

752

RS/A3-3GH-48G0.75

48x0.75

7/0.37

1.6

24.3/30.7

963