Welcome to ECBAY
Trunk coaxial Cable
Trunk coaxial Cable

Detailed Product Description


Physical Dimensions

Component

JX-500B
mm

JX-500L
mm

JX-500T
mm

Center Conductor

2.772.772.77

Dielectric

11.4311.4311.43
Outer Conductor12.3012.2012.70

Outer Conductor Thickness

----0.65

Jacket

14.2214.2214.22

Jacket Wall Thickness

1.001.000.76
Messenger2.772.772.77
 Mechanical Characteristics
Minimun Bending Radius(Jacket)
JX-500B6.0in.22cm
JX-500L6.0in.30cm
JX-500T6.0in.30cm
Minimun Breaking Strength of Messenger1800lbs.816kgf
Dielectric Adhesion>20N/5cm
 Attenuation (20,≤dB/100m)
Frequency(MHz)JX-500BJX500-LJX-500T
50.520.520.52
551.771.771.77
2113.583.583.58
2503.943.943.94
2704.074.074.07
3004.304.304.30
3254.494.494.49
3504.694.694.69
4005.025.025.02
4505.355.355.35
5005.675.675.67
5505.975.975.97
6006.276.276.27
7507.097.097.09
8657.687.687.68
10008.278.278.27
 
Notes:
1. Nominal copper thickness for CCA (kg/km):10% CCA
2. The braiding coverage must be above 80% if you select braiding shield.
 Electrical Characteristics
Capacitance50±3.0 nf/km
Impedance  75±2.5 ohms
Velocity of Propagation87%

Shielding Effectiveness
JX-500BJX-500LJX-500T
55MHz            ≥60dB 85dB100dB
300MHz          ≥70dB 90dB110dB
1000MHz        ≥70dB 90dB110dB

Return Loss (100% swept)
JX-500BJX-500LJX-500T
1470MHz          ≥ 22dB 20dB22dB
4701000MHz   ≥ 20dB 18dB20dB


Ads by Google