Welcome to ECBAY
Urine Sediment Analyzer
Urine Sediment Analyzer

Urine Sediment Analyzer: 1.Reagents: Cleanser pack, controls and calibrators 2.Sample Volume>2.0ml, aspiration volume is 0.5ml

Urine Sediment Analyzer AVE-762A

 

 

Technical Specifications:

 

-          Test Principle: Machine Vision based on Microscope, the golden standard examination.

 

-          Test items: RBC, WBC, epithelial cell, crystal, cast, bacteria, mucus etc., various visible particles in urine samples.

 

-          Test Mode: Automatic LP(10X) and HP(40X) lens switch to realize full-field scanning, images capture for all particles in urine samples and make identification, classification and counting.

 

-          Test Speed: Single channel high-precision stream-counting pool, 30-60 tests/hr

 

-          Sample Request: Native urine samples, no need prior centrifugation.

 

-          Sample Volume: >2.0ml, aspiration volume is 0.5ml.

 

-          RBC Phase Analysis: It helps to determine the source of hematuria, through analyzing the size, form and chroma of RBC, and gives result in statistics graphs.

 

-          Sample identification: Built-in bar code reader

 

-          Report Form: International standard quantitative unit (xx cell/µl) is adopted, and the comprehensive report includes chemical, physical, quantitative results and morphologic images.

 

-          Reagents: Cleanser pack, controls and calibrators.

 

-          Detection Rate: >98% at con. level of 5 cell/µl.

 

-          Accuracy: ≥95%

 

-          Repeatability: CV≤7%

 

-          Cross Contamination:≤1 cell/µl at Conc. level of ≤5,000 cell/µl; ≤2cell/µl at Conc. level of 5,000~10,000 cell/µl,.

 

-          Image Capture: High Definition Digital Video Camera.

 

-          Printer: Laser Printer.

 

-          Interface: USB, LAN, COM, bidirectional communication to LIS and HIS supportable.

 

-          Data Storage Capacity: ≥200,000

 

-          Computer Configuration: Current configuration in the market.

 

-          Dimensions: 560X515X475mm, Main unit weight: 48.5kg.

 

 

Test Parameters:

 

-          All particles in urine samples can be identified, counted and classified;

 

-          Real images and statistical graphs of Abnormal RBC(RBC phase) Morphological Analysis can be displayed and printed;

 

-          Chemistry test results received from the connected chemistry analyzer will be printed with physical test results to form a comprehensive report;

 

-          Expansion tests can be carried out, such as Hydrothorax, Cerebrospinal Fluid etc.

 

 

Product Advantage

 

Made strictly according to ISLH Recommended Reference Procedure for the Enumeration of Particles in Urine;

 

-          Uncentrifuged urine samples at cutoff concentration level of 3-5cell/µl can be detected;

 

-          Precise analysis of RBC phase timely helps to determine the source of hematuria;

 

-          Report verification and correction can be done on screen without any further manual microscopic examination;

 

-          Particles’ characteristic parameters stored in the database are reproducible for further clinical study;

 

-          Both standardized quantitation and morphological analysis display in graphic report;

 

-          The self-learning ability continuously improves the recognition accuracy;

 

-          The only instrument with reference values based on microscopy with uncentrifuged urine samples    from healthy people;

 

-          SFDA approved quality controls available.

 

 

Test Principle

 

Machine vision has been applied to morphological analysis, and realizes the identification, classification, counting of the urine particles automatically.

 

 

Core Technology:

 

(1)   Machine Vision technology:

 

   Automatically analyze and identify negative and positive samples, rapidly screen the negative samples.     Automatically identify, classify and count various urine formed elements by LP(10X) lens and then by HP(40X) lens.

 

  Automatic morphologic analysis insures objective and reliable test results. The positive samples only need verification on screen without any further manual microscopic examination.

   Conduct all parts of the equipment working harmoniously. No manual operation required in the whole process.

 

(2)   Automatic target locating and tracking technology

 

     LP(10X) Full-field scanning to locate all the targets, HP(40X) automatically tracking and enlarging the small targets to identify and classify their fine structures.

 

     Directly detect the native urine samples and effectively avoid the error caused by centrifugation.

 

 

Sampling System:

 

Precise pump and valve system filling-up counting chamber with sample urine automatically. Bi-directional cleaning the counting chamber, pipeline system and inner and outer sides of the probe. Effectively avoid cross contamination.

 

 

Full automatic Digital Biological Microscope

 

(1)   LP(10X) and HP(40X) switches automatically.

 

(2)   Auto-focusing microscope.

 

(3)   Auto-moving from left to right and scan the counting chamber line by line to realize the full-field scanning.

 

(4)   Condenser automatically adjusts the lights intensity.

 

 

Intelligent Self-Learning Function

 

The misidentified target will be memorized and used to update the database, and the automatic identification capacity will be improved step by step.

 

 

Quality Control

 

The self-test software running with the SFDA approved quality controls meets the quality control demand.

 

 

Urine Sediment Analyzer