ETCR9500C Three-Channel Wireless High Voltage Current Meter----New!
ETCR9500C Three-Channel Wireless High Voltage Current Meter----New!

Three-Channel Wireless High Voltage Current Meter 1.First and secondary loop current,variable ratio,phase 2.wireless 30m

ETCR9500C Three-Channel Wireless High Voltage Current Meter 

  

 . Technical Specifications

FunctionsThe on-line measurement and detection for primary and secondary current, transformation ratio, error, phase (group) difference, polarity, phase sequence, and leaker in the three-channel high & low voltage current transformer and the voltage transformers
Power supplyHV Detector:DC6V alkaline batteries (1.5V AAA × 4)Principal machine: DC6V alkaline batteries (1.5V AAA × 4)30-hour continuous operation available
Test modeClampCT, HV 1CT, LV3 CT double- shield
Transmission modeHigh-pressure tested data transmitted through wireless network, with a linear transmission distance of 20m;
RangeHV detector 1st: 0.1mA ~ 1000ALVcurrent clamp 2nd: 0.01mA ~ 10A
ResolutionHV detector: 0.1mA; LV current clamp: 0.01mA
Primary circuit test accuracy(23 °C ± 3 °C, below70% RH)0.0mA~9.99A:±1%±5dgt 
10.0A~49.9A: ±2%±5dgt 
50.0A~199.9A: ±3%±5dgt
200A~600A:  ±4%±5dgt   
601A~1000A:   ±5%±5dgt  
Secondary circuit test accuracy0.00mA~10A: ±1%±5dgt(three-channel being displayed in one screen)   (23°C±3°C,less than 70%RH)
CT ratioThree kinds of transformation ratio indications :(1)convert the transformation ratio based on the adjustable basic value of 5A for secondary circuit current; (2)convert the transformation ratio based on 10kV-YY of 10kV/380V, that means 1st means the current of the line under 380V, 2nd means the secondary circuit current of CT under the 380V, and then calculate the ratio between the 10KV line and the secondary circuit;(3)the measured current ratio can be calculated by the measured CT ratio between the primary and secondary circuit)
Reference RangeReference range of transformation: 0.00A ~ 99.99A, the default secondary circuit  current is transformed to 5A;
Range of Ratio error(F.Er)0.0% ~ 9.9%, the error between the measured CT ratio and the preset CT ratio
Range of CT ratio0000~9999/0.0A~9.9A
Range of Ratio error0.0%~9.9%,the principal machine can sound a alarm of “beep - beep – beep” if the measured value is more than the preset error.
Phase polaritySymbol  indicated for in-phase positive polaritySymbol  indicated for in-phase negative polarity
Indication of Phase SequenceCursor in clockwise rotation and“Positive Phase”  indicated for positive phase sequenceCursor in counterclockwise rotation and“NegativePhase”  indicated for negative phase sequence
Indication of ErrorSymbol “Error” indicated if  the tester can’t identify the phases, polarity,  and phase sequence properly;
Data Storage1500 sets of dada memory; press the Left arrow key to select data, and to save and auto-number the selected data (the good condition of data available under power-down or battery replacement)
Automatic  Recording Interval TimeFrom 00 minutes to 99 minutes, the tester stops automatic record if being set to 00 minutes; the principal machine doesn’t shut down automatically if being set from 01 minutes to 99 minutes.
Sampling rate3 times / sec
ShiftFull-automatic shift 
DimensionsPrincipal machine:W75mm × H170mm × T30mm;HV detector: W 76mm × H 255mm × T 31mm;LV current clamp: W 70mm × H115mm × T 38mm;
Clamp SizeHV detector clamp: φ48mmLVcurrent clamp: 25mm × 30mm
VoltageLess than 70kV voltage for line test(operation by being connected to 5 insolating rods required)
Display ModeLCD: 128dots × 64dots;backlight available for dark areas
LCD Size:44mm× 27mm;
Data RetentionPress the Left arrow key to retain the data ; press the Left arrow key to cancel retention if the symbol “HOLD” displays;
Data SearchPress the MEM key and the Arrow key to search data;
O verflow DisplayOverflow available if being out of range: the symbol “OL A” displayed;
Zero-signal indicationThe symbol “---" is shown if the principal machine can’t receive the signal from the HV detector;
Backlight ControlAvailable; ON / OFF means to open /close the backlight;
Alarm promptThe principal machine can sound an alarm of “beep - beep – beep” if the measured value is more than the preset error. and press the Right arrow key to launch or stop the alarm function;
Auto power-offAutomatic power-off available after about 15 minutes as of starting;
Battery voltageThe low- voltage symbol is displayed to remind user to replace the battery if the battery voltage is lower than 4.8V;
WeightPrincipal machine:240g (including batteries)HV detector: 335g (including batteries)LV current clamp: 150g × 3Total weight: 10kg (including instrument box and the insulating rods)
Requirements on InterferencesNo strong electromagnetic interference; no interference from 433MHz and 315MHz channel 
Operating temperature and humidity-25°C~45°C; less than 80%Rh
Storage temperature and humidity-10°C~60°C; less than 70%Rh  
I nsulating rod sizeOuter diameter φ32mm, inner diameter φ24mm, 1m /piece, 5 pieces
Lead length of LV current clamp2m/ Piece
Dielectric strengthAC100kV/rms between HV detector cover and the 5 th insulating rod; the AC1000V/rms between the principal machine and the LV current clamp shell between
StructureAnti-leak type II (HV detector)

 .Field Application

    

ETCR9500C Three-Channel Wireless High Voltage Current Meter----New!

Ads by Google


About Us | Contact Us | Help | Terms & Conditions
Hot Products: A | B | C | D | E | F | G | H | I | J | K | L | M | N | O | P | Q | R | S | T | U | V | W | X | Y | Z | 0-9
Copyright Notice @ 2008-2022 ECBAY Limited and/or its subsidiaries and licensors. All rights reserved.