General1. Model: CB7L-63

2. Standard: IEC61009-1

3. Function: Isolation&leakage protection

4. Rated voltage: 230V/400V

5. Rated current: 25, 40, 50, 63A

6. Frequency: 50/60Hz

7. HS Code: 85362000

8. Number of pole: 4 pole

9. Electrical endurance: 10, 000 times

10. Certificate: ISO9001: 2000, ISO14001: 1996, CE

Specifications

Electrical featuresRated current InA25, 40, 50, 63A
Type (wave form of the earth leakage sensed) A,   AC, AC~S, A~S
PolesP2,   4
Rated voltage UeV230/400
Insulation voltage UiV500
Rated frequencyHz50/60
Rated breaking capacityA6000,   10000
Rated impulse withstand voltage (1.2/50) UimpV6000
Rated sensitivity  IΔ nA0.03, 0.1, 0.3
Rated residual making and breaking capacity IΔ mA500(In=25/40A); 630(In=63A)
Pollution degree 2
Mechanical featuresElectrical lifet2000
Mechanical lifet2000
Protection degree IP50
Storage temperature° C-25~+70
Ambient temperature (with daily average≤ 35° C)° C-5~+40
InstallationTerminal connection type Cable / U-type bar / Pin-type busbar
Terminal size top/bottom for cable mm225
AWG18-3
Terminal size top/bottom for busbarmm225
AWG  18-3
Tightening torqueN*m2.5
In-Ibs.18
Mounting On DIN rail EN 60715(35mm) by means of fast clip device
Connection from top and bottom
 

CB7LE-63 Residual Current Circuit Breaker with Overcurrent Protection

Verified Information This information is Verified by Bureau Veritas and validity period is 2012/06/06 --- 2013/06/06 All the information below may covers both Gold Supplier and its related companies , Their Relationship will be affirmed according to china laws and regulations , also it will be clearly display in the full report >> Production Capacity: Product line name Production Line Capacity Actual Units Produced(Previous Year)
Circuit breaker, KWH meter, Power supply, Transformer, Switch cabinet, Explosion-proof products USD46,000,000 Per Month confidential
Export Market Distribution: Market Revenue(Previous Year) Total Revenue (%)
North America confidential 1.0
South America confidential 2.0
Eastern Europe confidential 3.0
Southeast Asia confidential 1.0
Africa confidential 3.0
Oceania confidential 1.0
Mid East confidential 3.0
Eastern Asia confidential 1.0
Western Europe confidential 1.0
Central America confidential 1.0
Northern Europe confidential 1.0
Southern Europe confidential 1.0
South Asia confidential 1.0
Domestic Market confidential 80.0
Production Machinery: Machine Name Brand & Model No. Quantity Number of Year(s) Used Condition
Nod welding machine DAK-Z25 70 2.5 Acceptable
Production auto flowing line No information 5 2.0 Acceptable
Auto moving printing machine No information 5 1.0 Acceptable
CNC pressing plate machine VT300 2 4.0 Acceptable
Auto inspection equipment No information 6 1.0 Acceptable
Auto surface mounting machine G310 1 1.0 Acceptable
Delay special nature calibration table YCM1-630 52 3.5 Acceptable
Ultrasonic cleaning machine Haohong 1 1.5 Acceptable
Age equipment No information 1 1.0 Acceptable
Testing Machinery: Machine Name Brand & Model No. Quantity Number of Year(s) Used Condition
NDT testing system ITUIS 1 1.0 Acceptable
Over current delay testing equipment YG-600 8 1.0 Acceptable
Electrical age testing apparatus No information 2 0.5 Acceptable
Mechanic age testing apparatus No information 4 1.5 Acceptable
Optics auto inspecting machine SMT-A01 1 0.5 Acceptable
KW meter inspection apparatus No information 34 1.0 Acceptable
Production Flow: 1.Auto welding 2.Auto surface mounting 3.Assembly 1 4.Assembly 2 5.Assembly 3 6.Assembly 5 7.Printing 8.Aging 9.Inspection 1 10.Inspection 2 11.Inspection 3 12.Inspection 4 13.Inspection 5 14.Package 15.Warehouse Certification: Certified Picture Certification Name Certified By Certificate No. Product Name & Model No. Available Date-Expired Date
CB ITS SE-62776 Circuit-breakers for Overcurrent Protection 2010/08/25 --- 2049/12/31
CB ITS FR610693 Circuit-breakers for Overcurrent Protection for Household and Similar Installations 2011/05/26 --- 2049/12/31
CE BV 1166AS05CGC5456 MCB 2011/05/30 --- 2049/12/31
CE VOP 052/2012/JZ Residual Current Circuit Breaker & YCL2, YCL362, YCL362N 2012/03/30 --- 2017/03/30
CE ETS G3M20407-1594-E-16 Residual Current Circuit Breaker & YCL362 2004/08/02 --- 2049/12/31
SEMKO ITS 1020244 Circuit-breakers for Overcurrent Protection 2010/08/25 --- 2013/01/31
CCC CQC 2008010307313985 Residual Current Operated Circuit-breaker 2011/01/04 --- 2016/01/04
Testing Report: Report Picture Report Name Report By Product Name & Model No. Report Date
EMC Test Report Shenzhen LCS Compliance Testing Laboratory Ltd. Residual Current Circuit Breaker & YCL362 2012/03/27

Ads by Google


About Us | Contact Us | Help | Terms & Conditions
Hot Products: A | B | C | D | E | F | G | H | I | J | K | L | M | N | O | P | Q | R | S | T | U | V | W | X | Y | Z | 0-9
Copyright Notice @ 2008-2022 ECBAY Limited and/or its subsidiaries and licensors. All rights reserved.