Detailed Product Description
TGM65 Mini Circuit Breaker
TGM65H IEC898/GB10963-199910KA
TGM65N IEC898/GB10963-19996KA
The MCB has the following function:
- Tripping off protection
- Overload protection
- Control
- Isolate
- Between TN & IT system as indirect contact protection
TGM65H MCB suitable for terminal distribution and industrial apparatus
RE: TGM65N Same As TGM2-63
Description
TGM65N MCB specification
Electrical Parameter
-Rated voltage: 440VAC
-Breaking Capacity (IEC898)
Rated Current(A) | Type | Voltage(V) | Breaking Capacity |
1-63 | 1P | 230~400 | 10 |
2/3/4P | 440 | 10 |
Grade of current limitation: 3
High-speed close: Make sure the impact load work safely, extend the electrical life of the breaker.
Isolation breaking location indicator:
When the green symbol in the handle on the breaking situation, it is indicated all the phase on the breaking location.
Mechanical Life(O-C): 20000 times
Environment:
Anti-wet and anti hot: 2 type (when the temperature is 55 C), the relative humidity 95%)
Type | 1P | 2P | 3P | 4P |
120 | 240 | 360 | 480 |
Connection: terminal connection area
-25A and under 25A 16mm2 multi flexible wires or
25mm2 single hard wires
-32A and under 32A 25mm2 multi flexible wires or
35mm2 single hard wires
C curve
Protect practice load and distribution cables
Electrical parameters
Rated current: 1-63A
Tripping Character: instant tripping 5-10IN
D curve
Protect start up the huge impact load (motor, transformer)
Electrical parameters:
Rated current:1-63A (30C)
Tripping Character: instant tripping 10-14IN