Welcome to ECBAY
shell-and-tube graphite falling film absorption
shell-and-tube graphite falling film absorption

1. large absorptive capacity to adjust range 2. in the 0.3-1.7 tons / day output

It’s mainly used for the production of hydrochloric acid,

when absorption of synthesis of hydrogen chloride gas,

has the advantages as following :

1.high absorptivity,  More than 99.9%

2.pressure fall within uptake system is lower

3.material temperature up to 250 °C into the absorber , does’t effect the  product acid concentration

4.the production of  low acid temperature, higher than the cooling water 3-15 °C, do not need the aftercooling

5.produce reagent grade hydrochloric acid without extra equipment

6.large operating flexibility, easy to control and adjust the open parking

7.equipment with corrosion-resistant, easy maintenance,long useful life

8.compact conformation  ,light weight

series table:

Model number

Heat exchange area

   (m2)

Absorptive capability

35%HCL t/d

Equipment weight

 (kg)

Style 1

Style 2

GX245-1/11-3

3

10

395

285

GX300-1/11-5

5

15

460

450

GX350-1/11-10

10

25

595

565

GX450-1/11-15

15

40

870

820

GX500-1/11-20

20

50

1035

1020

GX550-1/11-25

25

60

1255

1180

GX600-1/11-30

30

70

1535

1435

GX650-1/11-35

35

80

1825

1700

GX700-1/11-40

40

100

2145

1995

GX800-1/11-50

50

120

2675

2480

GX850-1/11-60

60

140

3280

2985

GX900-1/11-80

80

180

3945

3685

GX1000-1/11-100

100

230

4595

4305

GX1100-1/11-120

120

280

5260

4933

GX1200-1/11-140

140

GX1400-1/11-190

190

shell-and-tube graphite falling film absorption