Welcome to ECBAY
phone battery charger
phone battery charger

phone battery charger Got CE, FCC, RoHS also is an APPLE licensed manufacturer 8 years experience 1 year warranty

1,cellphone charger Application:

1.1 Clear, no nick, no distortion .

1.2 Dimensions: L(112)mm×W(58)mm×H(15.8)mm

Weight:121g 

2. mobilephone chargerTest standard condition

   The test should be under temperature+5°C~25°C,humidity40%~60% R.H if there is no special note.

3. mobilephone chargerTest method and machine

3.1 electronic load meter,DC,figure oscillograph.

The precision of test voltage meter should not less than 0.5 grade, the internal resistance should not less than 10KΩ/V; the precision of test current meter should not less than 0.5 grade, the test error of oscillograph should less than 0.5mV.

3.2 Thermometer

The meter precison of testing temperature should not less than±0.5°C.

3.3 Test internal resistance

The test meter of battery internal resistance, the frequency is AC 1KHZ.

4. portable charger Electronic performance

No.

Content

Standard

Test condidtion

Test method

1

Input volatge

5.2±0.5V

 

Test positive/negative pole of input voltage with voltage meter

2

Onput volatge

5.2±0.25V

With load 0~0.5A

Test positive/negative pole of output voltage with voltage meter

3

Test with load

5.2±0.25V

0.5A

Test positive/negative pole of output voltage with voltage meter

5.2±0.25V

0.35A

Test positive/negative pole of output voltage with voltage meter

5.2±0.25V

0.15A

Test positive/negative pole of output voltage with voltage meter

4

Wave and Noise

≤50mV

With load 0~0.5A

     Test positive/negative pole of output voltage with oscillograph 

5

Cycle life

≥500

0.5 Cdischarge

500times

After ful charge, discharge at 0.5C to over-discharge protection,cycle it 500 times, work the consistent time.

6

-10°C

Discharge performance

≥510min

0.5Cdischarge

After ful charge, put it in -20±2°C low temperature box, discharge at 0.5C to over-discharge protection , work the consistent time.

7

+55°C

Discharge performance

≥510min

0.5Cdischarge

After ful charge, put it in 55±2°C high temperature box, discharge at 0.5C to over-discharge protection , work the consistent time.

8

Charged keep

≥1200min

0.2Cdischarge

After ful charge, store it 28 days under 20±5°C, discharge at 0.2C to over-discharge protection , work the consistent time.

9

Capacity recovery after storage

≥1200min

Store 3 months,0.2Cdischarge

After ful charge, put it 90 days under normal temperature,then charge/discharge 3 times at 0.2C,one of them , the dischar time ≥570min

5. mobile phone charger Mechanism performance test

Content

Test condition

Judge standard

Vibration test

To 3 directions after full charge,at

10HZ~30HZ to scan cyclely 30min.

Vibration frequency  10HZ~30HZ  displacement amplitude (single amplitude of vibration 0.8mm)

The electric performances are OK after vibration.

Drop freely

After full charge, drop it from 1000mm height to positive and negative of total 6 directions of X,Y,Z, make it drop on the 18mm-20mm wooded board. 6 directions each.

The electric performances are OK after drop.

phone battery charger

Ads by Google


About Us | Contact Us | Help | Terms & Conditions
Hot Products: A | B | C | D | E | F | G | H | I | J | K | L | M | N | O | P | Q | R | S | T | U | V | W | X | Y | Z | 0-9
Copyright Notice @ 2008-2022 ECBAY Limited and/or its subsidiaries and licensors. All rights reserved.