Welcome to ECBAY
HUX model chemical tail gas complex absorbing column
HUX model chemical tail gas complex absorbing column

Detailed Product Description


 

Patent Number:ZL 96 2 23446.X

Tail gas from Chemical Industry can be absorbed,treated and recycled in one step(also can be recycling) by this column, simplifies the traditional multi-step cooling and absorbing . It can mainly be applied to Chemical Industry, Pesticides,Metallurgy Light Industry, Synthetics Fiber, Pharmaceutics and other industriestail gas: HCL,CL2,SO2,H2S,HF,P2O5,TO meet the environment protection standard of emission , and to recycle the by-products.

Technical propeties:

1.       Absorption rate:99%

2.       Absorbing quantity per day:3T/M220~25

3.       Max. spray flow of absorbent:140KG/h·m2

4.       Flow of cooling water:2T/h·m2

5.       Cooling water temperature:20~25

6.       Total heat transfer coefficient: K=732.69W/m2·

7.       Working temperature:-20~170

Design pressure:    Tube side:≤0.6MPa

                             Shell side: ≤0.2MPa

Specification:      HUX 30 treating inlet 9T/d

                          HUX 40 treating inlet 12T/d

                          HUX 100 treating inlet 150T/d

Or design and manufacture according to customers requirements