Motor
Our product is TUV approved, customers including Vaillant, Baxi, Baykan, Airfel etc.
Mina technical parameters for motor valve
Nominal voltage: AC 220V, 50Hz The voltage fluctuation allowed: -15% ~ +10% of the nominal voltage Insulation resistance: above 500mΩ measured by DC 500V megohmmeter Electric strength: the current leakage is below 10mAh under 1,800V, 50Hz for 1 min Idle power: 2.5 ± 0.1W under the nominal voltage Max. stroke: 7.5mm On/off time: Forward direction: 3.8s on, 0.2s off Reverse direction: 5.8s on, 0.2s off Contact area of the feeler: more than 2/3 of the feeler area Max. thrust: more than 55N Usage life: more than 200,000 Ambient environment: Ambient temperature: -25 - 70°C Relative humidity: less than 95% Without combustible or corrosive gas in the air, no electric dust This motor is for the reversing control of the boilerMotor