Welcome to ECBAY
anchor
anchor

Detailed Product Description


      The anchor is comprise capsule and rod(bolt).The anchor capsule is an epoxy-acrylic resin, styrene free, sands, and a benzoyl peroxide catalyst. They are non-expansive, stress-free anchors, and can be installed at closer center and edge spacings without reducing concrete load bearing capacity.Installation parameters:  

Chemical Anchor Capsule

Chemical Anchor Stub: Steel 5. 8 / stainless steel 316

Drill hole diameter

 

Depth of drill hole

Maximum Anchor thickness

Description

L [mm]

D [mm]

H [mm]

H [mm]

M10

130

12

90

20

M12

160

14

110

25

M16

190

18

125

35

M20

260

22

170

65

M24

300

28

210

65

M30

380

35

280

65

Average destroy load of individual anchor bolts:    Unit: KN

Chemical anchor

M10

M12

M16

M20

M24

Tension

C 30 concrete

Steel 5. 8

32.2

45.8

71.8

128.4

188.6

Stainless steel 316

36.8

58.8

76.9

137.7

196.6

Shear

C 30 concrete

Steel 5. 8

19.7

29.8

48.0

78.8

111.6

Stainless steel 316

27.4

36.6

63.7

100.8

119.6

Individual design load of anchor bolts: Unit: KN

Chemical anchor

M10

M12

M16

M20

M24

Tension

C 30 concrete

Steel 5. 8

10.9

16.2

23.1

42.7

59.6

Stainless steel 316

10.9

16.2

23.1

42.7

59.6

Shear

C 30 concrete

Steel 5. 8

12.1

17.7

33.0

51.4

74.2

Stainless steel 316

13.1

19.0

35.3

55.2

44.2

Spacing and Edge distance

     

M10

M12

M16

M20

M24

Effective anchorage depth

hef

[mm]

90

110

125

170

210

Characteristic spacing

scr,N

[mm]

220

270

310

420

520

Characteristic edge distance

ccr,N

[mm]

110

135

155

210

260

Minimum spacing

smin

[mm]

90

110

125

170

210

Minimum edge distance

cmin

[mm]

45

55

65

85

105

Min. thickness of concrete slab

hmin

[mm]

140

160

175

220

260

 

Installation:
1. Prefix drill hole using drill, maintaining the specified drill hole depth and drill hole diameter
2. Remove drill dust completely
3. Insert the right glass resin capsule
4. Turn stud into drill hole using drill attachment. Stop when the setting depth specified reaches the surface
5. The anchor is correctly fixed when the setting depth specified flushes with the drill hole surface and excess mortar is discharged from the hole. If excess mortar fails to come out of the drill hole, the anchor stud must be removed immediately
6. An additional capsule must be inserted along side to the previous capsule and the same procedure repeated to fix the anchor however at all times. Excess mortar shall be discharged from the hole to indicate proper fixing
7. Connect fixture at the end of the curing and tighten with nut the washer. After the appropriate setting time tighten the fixing and apply the work load.