Welcome to ECBAY
AAAC conductor
AAAC conductor

AAAC conductor is widely used for overhead power transimission,we can produce as per IEC,BS,ASTM,CSA,DIN,JIS Standard AAAC conductor of our factory under the standard of ASTM/BS/IEC.

AAC,AAAC,ACSR,AACSR&ACAR conductor widely used in power transmission lines with various voltage levels. since they have such good characteristics as simple structure, convenient installation and maintenance, low cost for the line, large transmission capacity and are also suitable for laying across rivers and valleys where special geographical teatures exist. 1. Specification: (1) all aluminium conductor (AAC)

(2) all aluminimum alloy conductor(AAAC)(3) aluminum conductor steel reinforced (ACSR) (4) anti-corrosion type ACSR (5) aluminimum conductor aluminimum clad steel reinforced(ACSR/AW)

(6)rear earth aluminimum conductor steel reinforced(ACSR/RE)

(7)aluminimum conductor aluminimum alloy reinforced(ACAR)2. Elative manufacturing standards: IEC83, IEC1089, 31, B232, BS215, DIN48204

1). Standard: IEC61089, BS215 part2, ASTM B232, DIN48204, BS EN50182 2). Specification: ACSR is composed by bare concentric-lay-stranded galvanized steel wire(s) with aluminum wires surrounded by one or more layers of helically. Greased ACSR can also be supplied. 3). Application: ACSR is widely used in overhead electric power transmission and distribution lines with various voltage levels

All Aluminum Conductor(AAC)& Aluminum Conductor Steel Reinforced(ACSR))for ASTM (AAC, ACCR, AAAC, ACSR) Generally Confirming to IS 398 (Part-I, II, IV), IEC-228 (AAAC) Conductor as per ASTM-B-399-1992 (AAAC) Conductor as per BS-3242-1970 (AAAC) Conductor IS: 398-IV-1994 (ACSR) as per ASTM-B-233-1992 (AAC) as per BS-215-1-1970 (AAC) as per IS-398-1: 1976 (AAC) as per ASTM-B-231-1990 (ACSR) as per IS: 398-II: 1976 & IS: 398-V: 1992 (ACSR) BS-215-II-1970 (AACSR) as per IEC-1089-1191 AAC(All aluminum conductor) are suited for overhead power line. We can supply this conductor according to different recognized standards, such as IEC61089, BS215, BS EN 50182: 2001, STM B231, CSA C49, DIN480201, JIS C3109, customer special specification also can be satisfied. ACSR or ACSR cable or ACSR conductor used for Overhead electrical distribution and transmission lines for distributing power Applications ccccUsed as bare overhead transmission cable and as primary and secondary distribution cable. ACSR offers optimal strength for line design. Variable steel core stranding enables desired strength to be achieved without sacrificing ampacity. Construction Aluminum alloy 1350-H-19 wires, concentrically stranded about a steel core. Core wire for ACSR is available with class A, B, or C galvanizing; ""aluminized"" aluminum coated (AZ); Or aluminum-clad (AW). Additional corrosion protection is available through the application of grease to the corer or infusion of the complete cable with grease. Specifications ACSR bare conductor meets or exceeds the following ASTM specifications: B-230 Aluminum Wire, 1350-H19 for Electrical Purposes B-231 Aluminum Conductors, Concentric-Lay-Stranded B-232 Aluminum Conductors, Concentric-Lay-Stranded, Coated Steel Reinforced (ACSR) B-341 Aluminum-clad Steel Core Wire for Aluminum Conductors, Steel Reinforced (ACSR/AW) B-498 Zinc-Coated Steel Core Wire for Aluminum Conductors, Steel Reinforced (ACSR/AZ) B-500 Zinc Coated and Aluminum Coated Stranded Steel Core for Aluminum Conductors, Steel Reinforced (ACSR) Notes Resistance is calculated using ASTM standard increments of stranding and metal conductivity of 61.2% IACS for EC (1350) and 8% IACS for steel. AC (60Hz) resistance includes current dependent hysteresis loss factor for 1 and 3 layer constructions. Current ratings are based on 75oC conductor temperature, 25oC ambient, 2ft/s wind, 96/watts/sq. Ft sun, 0.5 coefficients of emissivity and absorption.

NotesResistance is calculated using ASTM standard increments of stranding and metal conductivity of 61.2% IACS for EC (1350) and 8% IACS for steel. AC (60Hz) resistance includes current dependent hysteresis loss factor for 1 and 3 layer constructions. Current ratings are based on 75oC conductor temperature, 25oC ambient, 2ft/s wind, 96/watts/sq.ft sun, 0.5 coefficients of emissivity and absorption.

   

Code NameCode NameCode NameCode NameHigh  Strength  Strandings
TurkeyIbisEgretCurlewGrouse
SwanLarkFlamingoBluejayPetrel
SwanatePelicanGannetFinchMinorca
SparrowFlickerStiltBuntingLeghorn
SparateHawkStarlingGrackleGuinea
RobinHenRedwingBitternDotterel
RavenOspreyTernPheasantDorking
QuailParakeetCondorDipperCochin
PigeonDoveCuckooMartinBrahma
PenguinEagleDrakeBobolink 
WaxwingPeacockMallardPlover 
PartridgeSquabRuddyNuthatch 
OstrichWood DuckCanaryParrot 
LinnetTealRailLapwing 
OrioleKingbirdCardinalFalcon 
ChickadeeRookOrtlanChukar 
BrantGrosbeak  

AAAC conductor

Ads by Google


About Us | Contact Us | Help | Terms & Conditions
Hot Products: A | B | C | D | E | F | G | H | I | J | K | L | M | N | O | P | Q | R | S | T | U | V | W | X | Y | Z | 0-9
Copyright Notice @ 2008-2022 ECBAY Limited and/or its subsidiaries and licensors. All rights reserved.