Detailed Product Description


        JTQ - AEC2232dX series of toxic gas detection reviews can be allocated to multiple types of electrochemical sensors, the display of poisonous and harmful gas detection of air within the content (10-6 or %) concentration, VOL 4 ~ 20mA output and standard signal, also can output three group relay contacts signal (fault signal, high/low limit alarm signal), direct access DCS/RTU/EDS/PLC etc data acquisition system or other secondary instrument sound-light alarm output, and linkage to avoid malignant accidents.

        This series still has the following characteristics testing alarming device, highlighting LED display, Low/upper limit alarm concentration can be set, According to the concentration of gas calibration calibration value set.

        This series of testing alarming device adopts imported advanced electrochemical sensor and digital processing technology. Products with high sensitivity, stability testing, toxic, low consumption, etc.

        This series of testing alarming apparatus are widely used in petroleum, chemical, pharmaceutical, steel, special industrial workshop etc, and other places of existing toxic or harmful gases.

 

 

 

 

·         It adopts single-chip Microcomputer technology and high-sensitivity anti-virus gas sensor, capable of automatically adapting itself to environmental changes, adjusting sensors aged curve, and keeping constant alarming sensitivity.

·         Highlight LED scene shows, low/upper limit alarm concentration field setting.

·         Buttons, simple and convenient; calibration Iron calibration, no open operation.

·         4 - 20mA standard signal and three group relay contacts output can be fit for linkage of control system and the output control equipment.

·         Detect principle:

electrochemical

·         Detected gas

CO,H2,H2S,Cl2,SO2,O2,NH3,NO2,HCl,HCN,PH3,HF,SiH4, Etc..

·         Accuracy:

±5%F.S

·         Power supply:

DC24V±6V

·         Power consumption:

≤3W

·         Operating environment:

-20-+50; Relative Humidity≤93%incondensable

·         Output: 

4 - 20mA standard signal and three group relay contacts output

·         Display:

LED

·         Installation:

Hanging, suck, holding tube

·         Explosion proof connection thread:

G3/4   internal

·         Explosion-proof Class:

ExdCT6

·         Protection Class:

Up to IP66

·         Material:

Aluminum