Home lpg gas leakage detector alarm manufacturer
Home lpg gas leakage detector alarm manufacturer

Gas And Carbon Monoxide Detector Auto-reset after alarm;can work with electrovalve/exhaust fan Available for Natural gas, LPG,

Home lpg gas leakage detector alarm manufacturer

Model:JKD-806

                         

                                             

 

 

PRODUCT INTRODUCTION:

 

The product is wall mounted gas detector with high stability, It is used for detecting leaking gas. Advanced semiconductor sensor is adopted to ensure high stability and long life. It is convenient for mounting. The product is suitable for the safety of residential house, villas, hotels, markets, boarding house etc.

 

MAIN FEATURE:

 

*High Reliability Sensor

*Auto Reset after Alarm

*MCU Processing Adopted

 

*Auto Detect Sensor Failture

*Induced GAS/LPG and Natural Gas

*SMT Design, High Stability

TECHNIQUE DETAILS:

 

*Operating voltage:  220V AC *Rated power: ≤3W (220V AC power supply)*Warm-up time: 3-5 minutes*Alarm level: 10% LEL of Natural gas*Alarm indicator:  Corresponding Red LED flash *Malfunction indicator: Yellow LED on & Beeper long-buzz*Alarm sound: ≥85dB (within 1 meter)*Operating temperature: -10 to 50*Environmental humidity: ≤95% RH (No congelation)*Installation mode: Wall mounted*Alarm output: Relay output /sound & flash alarm*Dimension: 115*72*41mm

 

TEST:

 

To test the installed detector while using independently, you can give some gas around in distance of 5cm to the gas convection holes by using un-ignition lighter.

Testing frequently may result in reducing the sensitivity of the detector. The alarm density of gas is set according with the criteria of GB15322.2-2005.The Detector will stop alarm and resume to the detecting state while the gas density reduced to lower than the alarm level.

NORMAL MAINTENANCE:

 

Suggestion: the user must brush and clean the gas convection holes with a little cleanser every three months, and must retest the Detector after cleaning for preventing the cleanser into the Detector.

 

EMERGENCY ALARM TREATMENT:

 

The Detector alarms while the gas density in air exceed the alarm level. The relative treatments as below:1. Shut down the tube valve right away.2. Open the window and make the air flow rapidly.3. Extinguish all fire sources and do not use anything can make fire, e.g. lighters, matches, etc.4. Avoiding open or close the power all kinds of electric equipment.5. Check the reason of gas leaking, and notice the relative departments and professional persons in time.

 

  

Home lpg gas leakage detector alarm manufacturer