ModelDR-75-12DR-75-15DR-75-24DR-75-48DC output voltage12V15V24V48VOutput voltage range(Note:2)±2%±2%±1%±1%Rated output current6.3A5A3.2A1.6AOutput current range0-6.3A0-5A0-3.2A0-1.6AWave and noise(Note:3)100mVp-p100mVp-p150mVp-p240mVp-pInlet stability(Note:4)±0.5%±0.5%±0.5%±0.5%Load stability(Note:5)±1%±1%±1%±1%Efficiency76%76%80%81%Adjustable range for DC voltage10.8~13.2V13.5~16.5V21.6~26.4V%43.2~52.8V%AC input voltage range85~264VAC 47~63Hz;120~370VDCInput current1.8A/115V 0.9A/230VAC inrush currentCold-start current 30A/115V 60A/230VLeakage current<3.5mA/240VACOverload protection105%~150% Type: pulsing hiccup shutdown Reset: tuto recoveryOver-voltage protection13.8~16.2V13.5~16.5V27.6~26.4V43.2~52.8VTemperature coefficient±0.03%/°c(0~50°c)Setup, rise , hold up time1000ms, 60ms, 50ms/230VVibration10~500Hz, 2G 10min,/1cycle, Period for 60min, Each axesWithstand voltageInput and output internal: Input and encolsur: 1.5KvAC, Output and enclosure: 0.5KvACIsolation resistanceInput and output internal: Input and enclosure, Output and enclosure:500VDC/100MΩWorking temperature and humidity-10°c~+60°c(Refer to output derating curve), 20%~90%RHOverall dimension55.5×125.2×100mmWeight0.551Kgs 20PCS/14Kg/1.1CUFTSafety standardsMeet UL 1012 requiement (Not apply for the mark)EMC standardsMeet FCC PART 15 J Conduction class B