Welcome to ECBAY
SCN-1500
SCN-1500

Features:High reliability, low rippleExchange the input voltage 88~132VAC/176~264VAC CHOOSE BY SWITCHProtection characteristics: short circuit/overload/pressure/thermalBuilt-in distance open/shutdown and voltage compensation signal interfaceHas the parallel functionBy external 2 ~ 5 V voltage control, which can adjust the output voltage of the rated voltage of the in the range of 40% ~ 100% in valueBuilt-in dc electric fan forced air coolingTwo years warrantySize : 291*132*136mm (L*W*H)ModelSCN-1500-12SCN-1500-15SCN-1500-24SCN-1500-48outputDc output voltage12V15V24V48VOutput voltage tolerance±1%±1%±1%±1%Rated output current125A100A62.5A32AOutput current range0-125A0-100A0-62.5A0-32AOutput power1500W1500W1500W1536WRipple and the noise120mVp-p150mVp-p240mVp-p480mVp-pDc voltage adjustable scope+ 5%; By external 2 ~ 5 V voltage control, which can adjust the output voltage of the rated voltage of the in the range of 40% ~ 100% in valueStart, rise, keep time800ms, 50ms, 16ms Loaded withinputInput voltage range88~132VAC/176~264VAC CHOOSE BY SWITCH 47~63 Hz;290~370VDCExchange input current12A/ 230 VACefficiency83%84%85%87%Impulse current120A/230VLeakage current3.5 mA/240VACProtection characteristicsOverload protection110%~135%Protection way: current limiting,delay shut off, restartOvervoltage protection110%~135%Protection way: cut output, restartHigh temperature protectionTSW1 (power tube) temperature> 100 ℃, restart when cut off outputenvironmentWorking temperature, humidity-10℃~+65℃,20%~90 %RHKeep temperature, humidity-20℃~+85℃,10%~95 %RHVibrate resistance10~200Hz,2G 10min./ 1 cycle time, 60 minutes, the axissecurityCompression sexI/P-O/P, I/P-FG:1500VACInsulation resistanceI/P-O/P, I/P-FG, >100M Ohms / 500VDCstandardSafety standardsUL1950,CSA22.2,IEC60950EMC standardFCC Part 15 Class Aotherweight5.3Kg;Package2pcs/11kg/CARTONSpecial featuresDc voltage is adjustable, remote control and voltage compensation, parallel, and series-parallel function interface (reference terminal instructions)note1. All the parameters in has not specified, all is in 230 VAC voltage input, rated load and 25 ℃ conditions measuring income value.2. Ripple and noise voltage is in 20 MHz bandwidth oscilloscope take 12 inches twisted pair end with 0.1 mu and 47 u when capacitance measurement.3. Tolerance is voltage setting error, the voltage adjustment rate and adjust the sum total of the current rate.4. The power to consider as a device installed in final equipment, this equipment must be to make sure it’s EMC index.

Ads by Google

Related Searches

About Us | Contact Us | Help | Terms & Conditions
Hot Products: A | B | C | D | E | F | G | H | I | J | K | L | M | N | O | P | Q | R | S | T | U | V | W | X | Y | Z | 0-9
Copyright Notice @ 2008-2022 ECBAY Limited and/or its subsidiaries and licensors. All rights reserved.