... motor.It conforms to IEC60947-4-1. 1.ApplicationCJX2-N mechanical interlocking contactor is suitable for using in the circuits up to ... F330N3P330800400160CJX2-F3304N4P330800400160CJX2-F400N3P400800500200CJX2-F4004N4P400800500200CJX2-F500N3P5001000700250CJX2-F5004N4P5001000700250CJX2-F630N3P63012501000335CJX2-F6304N4P63012501000335CJX2-F800N3P80012501000400 CJX2-N Mechanical Interlocking Contactor
rated voltage 660V AC50/60Hz, current 620A for convertible controlling the motor mechanical interlocking ac contactor CJX2-N Mechanical Interlocking Contactor
Detailed Product Description 3TD Mechanical Interlocking Contactor(Magnetic Contactor,Electrical Contactor)Application:3TD Mechanical Interlocking Contactor is suitable for using in the circuits the rated voltage ... ,current 300A and for convertible controlling the motor.It is mechanical interlocking device which ensures contact changeover of the two convertible contacts ...
CJX4-d/f mechanical Interlocking Contactor CE,ISO9001 OEM Short leading time Professional manufacturer Specifications:TypeRated ... -D1701705590100100110CJX4-D20520563110110110129CJX4-D24524575132132132160CJX4-D300300100160200200220CJX4-D410410110220250250280CJX4-D475475148265280280355CJX4-D620620200335400400450 CJX4-d/f mechanical Interlocking Contactor
Detailed Product Description 1.ApplicationCJX2-N mechanical interlocking contactor is suitable for using in the circuits up to the ... AC 50Hz, current 620A, for convertible controlling the motor. This mechanical interlocking device ensures contact changeover of the two convertible contactors. It ...
... . Application: LC1-D(New Type) series AC Contactor is suitable for using in the circuits up to ... delay & machine-interlockingdevice etc, it becomes the delay contactor, mechanical interlocking contactor, star-delta starter.With the thermal relay, it is ... time delay and up to 2N/O or N/C protected contacts and 2 contacts and 2screen ... over the world. Schneider LC1-D/CJX2-D Electrical AC Contactor JX2-D09
... to the rated voltage 660V AC 50Hz or 60Hz CJX2-D series AC contactor is suitable for using in the circuits up ... the auxiliary contact block, timer delay & machine-interlocking device etc, it becomesthe delay contactor, mechanical-interlocking contactor, star-delta starter. With the thermal relay, it ...
IEC947-4 LCD-1 series AC contactor is suitable for using in the circuits up to ... auxiliary contact block, timer delay & machine-interlocking device etc., it becomes the delay contactor, mechanical interlocking contactor, star-delta starter. With the thermal relay ... 59LC1-D254025181115LC1-D325032211518.5LC1-D4060403418.530LC1-D508050392233LC1-D638063423037LC1-D8012580493745 CJX2 LC1 series AC Contactor
... the auxiliary contact block, timer delay & machine-interlocking device etc, it becomes the delay contactor, mechanical-interlocking contactor, star-delta starter. With the thermal relay ... combined into the electromagnetic starter. The Contactor is produced according to IEC 947-2, VDE 0660 & BS5452.SPECIFICATION CJX2-D series ac ...
suitable for the circuit of AC 50HZ or 60HZ,voltage up to 660V,current up to 95A for reversible controlling. CJX2-N series machanical interlocking contactor
Detailed Product Description Ac contactor (interlocking contactor) specificationsInclude model number: AA01-09N, AA01-12N, AA01-18N, AA01-25N, AA01-32N, AA01-38N, AA01-40N, AA01-50N, AA01-65N, AA01-80N, AA01-95N, Their specifications are similar with the contact whitout "N".
... to use 3,the best quality and the best price CJX2-N series AC contactors are suitable for frequency 50/60Hz,rated ... starter. The products comply with IEC60947-4.SPECIFICATIONS of AC CONTACTOR CJX2(NEW)TypeRated Power KW/HP( AC-3 )IEC60947-4-1 ... .60.9516CJX2-D95new25/3545/6045/6011095651306601NO+1NC/1.60.95 CJX2-N LC1-N AC Contactor
... ISO9001,14001,IEC60947-4-1 CJX2/LC1-D AC contactorCJX2(LC1-D) NEW series AC Contactor is suitabie for using ... contact block, timer delay & machine interlocking device etc,It becomes the delay contactor,mechanical interlocking contsctor,star-delta starter with the thermal ... into the electromagnetic starter.The Contactor is produced according to IEC 60947-4,GB14048-4.Specification: CJX2/LC1-D AC ...
... ;ISO9001:2000 *OEM DELIXI CJX2-0910 AC Magnetic contactor: CJX2(LC1-D) NEW series AC Contactor is suitabie for using in ... contact block, timer delay & machine-interlocking device etc, it becomes the delay contactor, mechanical interlocking contsctor,star-delta starter. With the ... combined into the electromagnetic starter. The Contactor is produced according to IEC 60947-4,GB14048-4. CJX2 LC1-D0910 AC ...
Hot Products: A | B | C | D | E | F | G | H | I | J | K | L | M | N | O | P | Q | R | S | T | U | V | W | X | Y | Z | 0-9
Copyright Notice @ 2008-2022 ECBAY Limited and/or its subsidiaries and licensors. All rights reserved.